این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 2 دی 1404
Tanaffos
، جلد ۱۴، شماره ۱، صفحات ۴۲-۴۸
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Efficacy of the New Perilaryngeal Airway (CobraPLA™) Versus the Laryngeal Mask Airway (LMA™) to Improve Oropharyngeal Leak Pressure in Obese and Overweight Patients
چکیده انگلیسی مقاله
Background: This study aimed to evaluate the applicability of Cobra perilaryngeal airway (Cobra PLATM) for obese patients under general anesthesia and also to compare the results with those of classic laryngeal mask airway (LMATM). Materials and Methods: Seventy-three overweight and obese patients were included in this study. The patients were randomly assigned to LMATM or Cobra PLATM groups. Time required for intubation, successful intubation attempt, airway sealing pressure and incidence of complications including blood staining, sore throat and dysphagia were assessed and noted. Results: Thirty-six and 37 patients were randomly allocated to LMATM and Cobra PLATM groups, respectively. Most patients were males and had Mallampati Class II airway in both groups. The first attempt and overall insertion success for Cobra PLATM was significantly higher compared to LMA (p <0.05). Airway insertion was more successful (P = 0.027; 94% vs. 77%) with Cobra PLATM. Insertion times were similar with Cobra PLATM and LMA™ (Cobra PLATM, 29.94±16.35s; LMA™, 27.00±7.88s). The oropharyngeal leak pressure in the Cobra PLATM group (24.80±0.90 H2O) was significantly higher than that in LMA™ group (19±1 H2O, p <0.001). Sore throat was more frequent in the LMA™ group although it did not reach statistical significance (Fisher’s exact test, P = 0.33). Blood staining on airway tube was seen in both groups with a higher incidence in the Cobra PLATM group (Fisher’s Exact test, P = 0.02). Incidence of dysphagia was not different between the two groups. Conclusion: CobraPLA™ was found to be safe with low complications. It provided better airway sealing with high rate of the first insertion success for use in obese and overweight patients. This study recommends the use of CobraPLA™ as a rescue device in emergency situations for obese and overweight patients.
کلیدواژههای انگلیسی مقاله
CobraPLA™,Flexible laryngeal mask airway,Obese patients
نویسندگان مقاله
Siamak Yaghoobi |
Department of Anesthesiology, Qazvin Medical University Science, Shahid Bahonar, Qazvin, Iran,
Seyed Mohamadrezai Abootorab |
Department of Anesthesiology, Qazvin Medical University Science, Shahid Bahonar, Qazvin, Iran,
Hamid Kayalha |
Department of Anesthesiology, Qazvin Medical University Science, Shahid Bahonar, Qazvin, Iran,
Tom C Van Zundert |
University of Maastricht, Maastricht, The Netherlands
Amir H Pakpour |
Department of Public Health, Qazvin University of Medical Sciences, Qazvin, Iran.
نشانی اینترنتی
https://www.tanaffosjournal.ir/article_240886_587a447cdf9ea571159e2ff914db06a7.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات