این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 30 آذر 1404
Tanaffos
، جلد ۷، شماره ۱(winter)، صفحات ۵۸-۶۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Accuracy of Chest X-Ray in the Diagnosis of Tracheobronchial Foreign Bodies in Children
چکیده انگلیسی مقاله
Background: Tracheobronchial foreign body (TFB) aspiration is a common cause of mortality and morbidity in early childhood. The aim of this study was to evaluate the diagnostic value of chest x-ray in tracheobronchial foreign body aspiration among a group of Iranian children. Materials and Methods: We evaluated 32 children who underwent bronchoscopy for suspected airway foreign bodies. We reviewed the patients' age, symptoms, duration of symptoms, prebronchoscopy posterior-anterior x-rays, type of foreign body, and anatomic location of foreign body. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and accuracy indices of chest x-ray for the diagnosis of TFB aspiration were measured in this study. Results: The mean age of patients was 30 months (range 6–54 months), and 19(59.4%) were males. Among 32 patients who underwent bronchoscopy, foreign body was found and removed in 26 (81.2%) of them. Foreign bodies observed were the hull of nuts in 10 (38.5%), pomegranate seeds in 6 (23%), beans in 4 (15.4%), and some food products such as meat in two (7.7%) children. Chest x-ray was normal in 12 patients (37.5%). The most common symptom was cough in 80% of patients; followed by wheezing in 60%, tachypnea in 40%, dyspnea in 20%, and stridor in 5%. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of expiratory chest radiography in this study were 65%, 50%, 85%, 25%, and 62.5%, respectively. Conclusion: Chest x-ray is not specific for diagnosis of foreign body aspiration, and a normal chest x-ray does not always rule out the diagnosis of foreign body aspiration in patients with a history suggestive of foreign body aspiration and positive physical examinations. (Tanaffos 2008; 7(1): 58-62)
کلیدواژههای انگلیسی مقاله
Foreign Bodies,Chest X-ray,Bronchoscopy
نویسندگان مقاله
Hamid Reza Mansourian |
Department of Radiology, Shaheed Sadoughi University of Medical Sciences, YAZD – IRAN
Abdol-Reza Sadrearhami |
Department of Radiology, Shaheed Sadoughi University of Medical Sciences, YAZD – IRAN
Amir Abbas Shadman Yazdi |
Department of Radiology, Shaheed Sadoughi University of Medical Sciences, YAZD – IRAN.
نشانی اینترنتی
https://www.tanaffosjournal.ir/article_241275_b239d0877b084545e8687ec8f1c4c377.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات