این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Analytical and Bioanalytical Electrochemistry
، جلد ۱۵، شماره ۵، صفحات ۳۵۶-۳۷۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Voltammetric Determination of Trace Methyl Parathion using Electrochemically Reduced Graphene Oxide Modified Carbon Screen-Printed Electrodes
چکیده انگلیسی مقاله
Timely, efficient on-site detection of pesticides such as methyl parathion (MP) is crucial to ensure public health. This study introduces the first disposable electrochemically reduced graphene oxide (ErGO) modified electrode for rapid MP detection. A square wave anodic stripping voltammetry method for the detection of MP was developed using these ErGO-modified carbon screen-printed electrodes. Based on this study, graphene’s high electric conductivity and unique structure enhanced the sensitivity of the electrode for MP detection. Following optimization of the pH, equilibrium period, deposition potential, and period, the methodology demonstrated high sensitivity and reproducibility. Using the enhanced experiment conditions, calibration experiments were performed with a concentration range of 0 to 150 µg L
-1
of MP. A consistent oxidation peak was observed at -0.180 V. The calibration data showed the increase in the peak height was linearly correlated to the increase in MP concentration, with a correlation coefficient of 0.9854. The sensitivity of the developed methodology was 0.0887 µA (µg L
-1
)
-1
, and the limit of detection was 9.06 µg L
-1
. The methodology was successfully applied to multiple water samples, specifically river water, groundwater, and General Test Water, with recovery rates of 106.01% (standard deviation = 1.46%), 109.51% (standard deviation=0.44%), and 97.69% (standard deviation=1.49%), respectively.
کلیدواژههای انگلیسی مقاله
Methyl parathion,Screen-printed electrode,Reduced graphene oxide,Square wave anodic stripping voltammetry
نویسندگان مقاله
Hesameddin Azimi |
Department of Civil and Environmental Engineering, University of Massachusetts Lowell, Lowell, MA, USA
Connor Sullivan |
Department of Civil and Environmental Engineering, University of Massachusetts Lowell, Lowell, MA, USA
Dingnan Lu |
Department of Civil and Environmental Engineering, Ningbo University, Zhejiang, China
Eric Brack |
U.S. Army Natick Soldier Systems Center, Natick, MA, USA
Christopher Drew |
U.S. Army Natick Soldier Systems Center, Natick, MA, USA
Pradeep Kurup |
Department of Civil and Environmental Engineering, University of Massachusetts Lowell, Lowell, MA, USA
نشانی اینترنتی
https://www.abechem.com/article_705134_562f95acfffecbc2916bfb7969131f5f.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات