این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 22 آذر 1404
Analytical and Bioanalytical Electrochemistry
، جلد ۱۵، شماره ۳، صفحات ۲۲۹-۲۳۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Quantitative Determination of Duloxetine Hydrochloride in Biological Samples of Blood Serum and Urine Using a Novel Potentiometric Sensor
چکیده انگلیسی مقاله
In this work, a potentiometric sensor was developed based on polyvinyl chloride (PVC), duloxetine tetraphenylborate ion pair, various plasticizers of dioctyl phthalate (DOP), benzyl butyl phthalate (BBP), di(2-ethylhexyl)phthalate (DEPH), tris(2-ethylhexyl) phosphate (TEPH), dibutyl butyl phosphonate (DBBPh), dibutyl phthalate (DBP), dioctyl sebacate (DOS), dibutyl sebacate (DBS), 2-nitrophenyl octyl ether (NPOE) and di-octyl phthalate (DOPH)
)
and
THF as membrane solvent. The electrode responses at various contents of PVC and plasticizer were recorded to optimize their percentage compositions, and the best Nernst response (59.7) was obtained. The linear concentration range for this electrode made by optimal composition is 0.7 µM to 0.1 M with a detection limit of 0.3 µM. The response time of the ion-selective electrode based on the duloxetine-tetraphenylborate ion pair was determined. The effect of pH on the potential of duloxetine hydrochloride (DHCl) solution with a concentration of 1.0 mM was studied. Moreover, the performance of the prepared electrode was studied over two months to investigate the constructed membrane electrode’s stability. The selectivity coefficients of the electrode for determination of DHCl in the presence of some ions and molecules including Na
+
, K
+
, Li
+
, Ni
+
, Mg
2+
, Cd
2+
, Zn
2+
, Mn
2+
, Fe
2+
, Ca
2+
, Cu
2+
, Co
2+
, Cr
2+
, ascorbic acid, D-fructose, sucrose, aspartic acid, L-H-histidine, dopamine, glucose, uric acid, propranolol, dexamethasone and melatonin were determined using a separate solution method (SSM) and an adapted potential method. The application of the proposed sensor to determine DHCl in two biological matrices, including blood serum and urine samples, was also investigated.
کلیدواژههای انگلیسی مقاله
Potentiometric sensor,Ion selective electrode,Duloxetine hydrochloride (DHCl),Duloxetine tetraphenylborate ion pair,Polyvinyl chloride (PVC)
نویسندگان مقاله
Parvin Pourhakkak |
Department of Chemistry, Payame Noor University, 19395-4697, Tehran, Iran
Mohammad Ali Karimi |
Department of Chemistry, Payame Noor University, 19395-4697, Tehran, Iran
Hossein Tavallali |
Department of Chemistry, Payame Noor University, 19395-4697, Tehran, Iran
Mohammad Mazloum Ardakani |
Department of Chemistry, Faculty of Science, Yazd University, Yazd, 89195-741, I.R. Iran
Pouran Pourhakkak |
Department of Chemistry, Payame Noor University, 19395-4697, Tehran, Iran
Eisa Rahimi |
Department of Chemistry, Payame Noor University, 19395-4697, Tehran, Iran
نشانی اینترنتی
https://www.abechem.com/article_703903_119b9854d118090efbf7425bb2d98c79.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات