این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 25 آذر 1404
Analytical and Bioanalytical Electrochemistry
، جلد ۱۴، شماره ۷، صفحات ۶۶۷-۶۷۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Direct Potentiometric Evaluation of Trazodone Hydrochloride by Novel Ion Selective Electrodes
چکیده انگلیسی مقاله
This study improved three potentiometric sensors for measuring the drug trazodone hydrochloride. The constructive sensors were designed for the preparation of electro-active plasticized membranes representative of ion-association complexes. Trazodone cation and phosphomolybdate acid anions used a plasticized poly(vinyl chloride) membrane sensor acting as an electro-active material in a plasticized polyvinyl chloride electrode. The sensors showed agreement at near-Nernstian responses for trazodone hydrochloride-phosphotungstic acid-di-butyl phthalate and trazodone hydrochloride-phosphotungstic acid-o-Nitro phenyl octyl ether with lower detection limits of approximately 2.8×10
-6
mol.L
-1
and 1.1×10
-6
mol.L
-1
, while the slopes were found to be around 55.00 and 51.70 mV/concentration decade. The pH ranges were approximately 2.0-7.5, 2.5-8.0, and 3.0-8.0 for trazodone hydrochloride-phosphotungstic acid-di-butyl phthalate, trazodone hydrochloride-phosphotungstic acid-o-Nitro phenyl octyl ether and trazodone hydrochloride-phosphotungstic acid-di-butyl phthalate, respectively. The sensor hydrochloride-phosphotungstic acid-di-butyl phthalate showed small values of the slope near the 31.20 mV/concentration decade, while the detection limit was around 5.0×10-
6
mol.L
-1
. The three sensors indicated a high selectivity for the TRZ drug over several inorganic cations for different drug formulation samples. The dissolution profiles showed good relationships when plotted for use in the proposed sensor at optimum electrode conditions. The investigated sensors can be applied for the direct determination of TRZ in some pharmaceutical preparations, and can be used for the investigation of many TRZ tablets.
کلیدواژههای انگلیسی مقاله
Ion elective electrodes,Potentiometric method,Trazodone hydrochloride,PVC membrane,sensor
نویسندگان مقاله
Amina M Abass |
Department of Chemistry, College of Science, Al-Nahrain University, Baghdad, Al-Jaderia, Iraq
Sahar S M Alabdullah |
Department of Chemistry, College of Science, Al-Nahrain University, Baghdad, Al-Jaderia, Iraq
Ahmed Z M Albassam |
Materials Centre, School of Chemistry, University of Leicester, Leicester LE1 7RH, UK
نشانی اینترنتی
https://www.abechem.com/article_253949_36df9c55e64caa38abf20d723e211b86.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات