این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Analytical and Bioanalytical Electrochemistry، جلد ۱۳، شماره ۱، صفحات ۱۳۹-۱۵۹

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Determination of Dexamethasone disodium phosphate using potentiometric sensors based on molecularly imprinted polymer in flow injection and batch systems
چکیده انگلیسی مقاله Dexamethasone disodium phosphate (DSP) is one of the medications used for treatment of inflammatory diseases. In this work, a potentiometric sensor, based on a non-covalent imprinted polymer, was fabricated for the determination of DSP in pharmaceutical formulations. The molecularly imprinted polymer (MIP) was synthesized by precipitation polymerization using DSP as a template molecule, methacrylic acid as a functional monomer and ethylene glycol dimethacrylate as a cross-linking agent. The sensor was developed by dispersing the DSP imprinted polymer particles in o-nitrophenyl octyl ether plasticizer and embedding in poly(vinyl chloride) matrix. MIP was used as a suitable ionophore for the preparation of novel polymeric membrane (PME) and coated graphite (CGE) DSP-selective electrodes. The electrodes exhibit a Nernstian behavior for DSP ions over wide concentration ranges (1.0×10-7 - 1.0×10-1 M for PME and 1.0×10-8 - 1.0×10-1 M for CGE, Nernstian response (27.25 mV/decade for PME and 28.11 mV/decade for CGE), very low limits of detection (6.8×10-8 M for PME and 6.3×10-9 M for CGE), fast response time (~15 s for PME and ~10 s for CGE) and a satisfactory long-term stability (3 months) are characterizations of the proposed sensor. The sensor showed a high selectivity and a sensitive response to the template in aqueous system. The CGE was used in flow injection potentiometry and resulted in well-defined peaks for DSP ions with stable baseline, excellent reproducibility and very high sampling rate of 180 injections per hour. The proposed FIP system was used for the determination of trace DSP in pharmaceutical formulations.
کلیدواژه‌های انگلیسی مقاله Molecularly imprinted polymer,Flow injection poetntiometry,coated graphite electrode,Dexamethasone disodium phosphate,Biosensor

نویسندگان مقاله Marzieh Majdi |
Department of Chemistry, University campus 2, University of Guilan, Rasht, Iran

Farhang Mizani |
Department of Chemistry, Faculty of Science, Payame Noor University, 19395-4697, Tehran, Iran

Ali Mohammad-khah |
a Department of Chemistry, University campus 2, University of Guilan, Rasht, Iran b Department of Chemistry, Faculty of Science, University of Guilan, P.O. BOX: 41938-33697, Rasht, Iran


نشانی اینترنتی https://www.abechem.com/article_245924_d17476ca3aa07af29aabb53b90bcf309.pdf
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات