این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 6 دی 1404
Analytical and Bioanalytical Chemistry Research
، جلد ۱۰، شماره ۴، صفحات ۴۳۵-۴۴۳
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
MIP/GO/GCE Sensor for the Determination of Aminophylline in Pharmaceutical Ingredients and Urine Samples
چکیده انگلیسی مقاله
A new selective molecular imprinted polymer (MIP) was synthesized for electrochemical sensing of aminophylline (AMI). The MIP was fabricated via the co-polymerization of different monomers (acrylamide and methacrylic acid) around the template (AMI) in the presence of a cross-linker (ethylene glycol dimethacrylate) and an initiator (potassium persulfate). The prepared polymers were characterized by CHN elemental analysis, Fourier-transform infrared spectroscopy, atomic force microscopy, and scanning electron microscopy. For electrochemical applications, a voltammetric sensor was constructed by dropping MIP on the glassy carbon electrode surface after modification with the graphene oxide. Electrochemical determinations were achieved using differential pulse voltammetry (DPV), which indicated a wide range (3.7×10-11- 1×10-3 mol L-1) of AMI and a low detection limit (2.1×10-12 mol L-1). Alternatively, MIP was immobilized on a plasticized PVC membrane and deposited as one layer on the GCE to fabricate the potentiometric sensor. In the same context, a potentiometric sensor was constructed and exhibited a linear calibration curve in the concentration range of 2.6×10-9 mol L-1 to 3.1×10-3 mol L-1, with a detection limit of 1.5×10-10 mol L-1. Additionally, the developed methods displayed great selectivity for AMI compared to other competing molecules, high repeatability, and stability. In addition, the proposed methods were successfully applied for AMI detection in pharmaceutical drugs with recovery values (98.2 - 99.6%).
کلیدواژههای انگلیسی مقاله
Aminophylline,Bronchodilator drug,Molecularly imprinted polymer,Electrochemical sensors
نویسندگان مقاله
Aya Saher |
Mansoura Univesity
Ahmed Bahgat |
Mansoura Univesity
Ahmed Molouk |
Mansoura Univesity
Wael Mortada |
Mansoura Univesity
Magdi Khalifa |
Mansoura Univesity
نشانی اینترنتی
https://www.analchemres.org/article_173175_ab97f879c3e6e63f3e97b3192d29015d.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات