این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Aerospace Science and Technology، جلد ۱۶، شماره ۲، صفحات ۷۴-۸۵

عنوان فارسی Numerical Study of Flattened Miniature Heat Pipe with Hybrid Porous Wick and Double Heat Sources
چکیده فارسی مقاله Designing flattened miniature heat pipes (FMHPs) for electronic devices is a challenging issue due to high heat flux and limited heat dissipation space. It requires understanding the combined effects of the sintered-grooved wick structure, double heat sources, and flat thickness on heat pipes' thermal efficiency. Therefore, the aim of this study is to numerically investigate the effects of the FMHP with a hybrid wick on the thermal performance of its double heat sources acting as the CPU and GPU in notebook PCs. A transient 3D finite volume method was used to solve the governing equations and assisted boundary conditions. The cylindrical heat pipe with a 200 mm length and 6 mm outside diameter is flattened into 2, 2.5, 3, and 4 mm final thicknesses (FT). The obtained results show that the final critical thicknesses with the lowest thermal resistance are 2.5 and 3 mm for hybrid and grooved wick structures, respectively. Therefore, FMHP with hybrid wicks can be flattened about 8% more. Hybrid wick structures have the best effect on FMHP thermal performance at FT=2.5 mm
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Numerical Study of Flattened Miniature Heat Pipe with Hybrid Porous Wick and Double Heat Sources
چکیده انگلیسی مقاله Designing flattened miniature heat pipes (FMHPs) for electronic devices is a challenging issue due to high heat flux and limited heat dissipation space. It requires understanding the combined effects of the sintered-grooved wick structure, double heat sources, and flat thickness on heat pipes' thermal efficiency. Therefore, the aim of this study is to numerically investigate the effects of the FMHP with a hybrid wick on the thermal performance of its double heat sources acting as the CPU and GPU in notebook PCs. A transient 3D finite volume method was used to solve the governing equations and assisted boundary conditions. The cylindrical heat pipe with a 200 mm length and 6 mm outside diameter is flattened into 2, 2.5, 3, and 4 mm final thicknesses (FT). The obtained results show that the final critical thicknesses with the lowest thermal resistance are 2.5 and 3 mm for hybrid and grooved wick structures, respectively. Therefore, FMHP with hybrid wicks can be flattened about 8% more. Hybrid wick structures have the best effect on FMHP thermal performance at FT=2.5 mm
کلیدواژه‌های انگلیسی مقاله Flattened heat pipe,hybrid wick,thermal resistance,numerical simulation

نویسندگان مقاله G. R. Abdizadeh |
Aerospace Engineering Department, Amirkabir University of Technology

Sahar Noori |
Aerospace Engineering Department, Amirkabir University of Technology

Mohammad Saeedi |
Mechanical Engineering Department, Dalhousie University, Halifax,Canada

Hamidreza Tajik |
Satellite Research Institute, Tehran, Iran


نشانی اینترنتی https://jast.ias.ir/article_175533_3ac369693c2ee98a8328565229e94348.pdf
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en