Journal of Applied Fluid Mechanics، جلد ۱۵، شماره ۳، صفحات ۸۸۹-۹۰۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی A Study on Booster Pump System with Flow Sensor for Individual Flow Control Method
چکیده انگلیسی مقاله Booster pump system (BPS) can control the number of revolutions through an inverter by combining two or more vertical or horizontal centrifugal pumps in a series. Efficiency and energy savings, the most appealing aspects of booster pump systems, can be improved by controlling the operating conditions of individual pumps by measuring the flow rate of each pump. For improved operation, a booster pump system with a flow sensor to detect individual pump flow rates and a control algorithm to manage each low and high flow rate pump’s revolutions per minute are critical. To achieve this, first, the turbine-type flow sensor was developed through computational fluid dynamics and experimentation. The flow sensor was improved using computational fluid dynamics, and its accuracy was validated through experiments. The resulting flow measurement accuracy of the designed flow sensor was within 4%, with a measurement uncertainty of 0.4%. In addition, an experimental pump facility was built and used to evaluate booster pump system performance to investigate the energy saving rate. Then, after driving one low-flow rate pump at a set pressure, the flow and frequency control operation algorithm was used. This algorithm increased the allowed output of the drive pump by increasing the inverter’s frequency. When the frequency corresponding to the allowed output is achieved in the low-flow rate pump rather than the high flow rate pump, power savings increased due to the low-flow rate pump’s extended drive range. The investigations on the developed system’s energy consumption revealed that the energy savings were approximately 6.2% compared to the conventional system, depending on the system in question. The development of a booster pump system with a flow sensor was tested, and it was found to be effective.
کلیدواژه‌های انگلیسی مقاله Booster pump, Flow sensor, Computational fluid dynamics, Experiment, Energy consumption

نویسندگان مقاله M. Rakibuzzaman |
Department of Mechanical Engineering, International University of Business Agriculture and Technology, Dhaka 1230, Bangladesh

H. H. Kim |
School of Mechanical Material Convergence Engineering, Gyeongsang National University, Jinju 52725, South Korea

K. W. Kim |
School of Mechanical Engineering, Soongsil University, Seoul 06978, South Korea

S. H. Suh |
School of Mechanical Engineering, Soongsil University, Seoul 06978, South Korea

Y. S. Bae |
Sego Industry Pump, Bongsu-daero, Seo-Gu, Incheon, Gyeonggi-do 22845, South Korea


نشانی اینترنتی https://www.jafmonline.net/article_2037_ca9a6718dec6a80d505f6250d203bd09.pdf
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات