این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Applied Fluid Mechanics، جلد ۱۴، شماره ۵، صفحات ۱۵۳۵-۱۵۴۶

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Flow and Heat Transfer Performance of Channels with ‎‎45 Degree Ribs in Staggered Array‎
چکیده انگلیسی مقاله The cooling efficiency of blade is growing demand with increasing turbine inlet temperature in gas ‎turbine development. Ribs used in cooling channels is a common cooling structure, therefore, many ‎configurations were studied by previous literatures, including angle, spacing, shape etc. However, there ‎are less research about the dislocation ribs structure. In this paper, the 45-deg parallel ribs, crossed ribs ‎and dislocation ribs were investigated by numerical simulation, in order to reveal the heat transfer ‎performance and flow mechanism. Refer to the experiment, SST k-ω model was applied in steady ‎simulation, at Re from 20000 to 50000. Due to the angled ribs can induce the secondary flow and ‎generate small helical vortices at front corner, heat transfer performance was elevated. The large rotating ‎vortices influenced by the ribs arrangement occupy the center channel, thence the dislocation caused ‎different flow and heat transfer results. The results shown that parallel rib has higher heat transfer ‎enhancement than crossed ribs, but pressure loss possess considerable level. At Re=21587, the averaged ‎turbulent kinetic energy of Case2.2 with dislocation ribs is 22.4% lower than parallel ribs. The all 45-deg ‎crossed ribs present higher level of overall thermal performance, and Case2.2 is optimal for the range of ‎Re investigated‎.
کلیدواژه‌های انگلیسی مقاله Internal cooling, Numerical simulation, Ribs, Gas turbine, Heat transfer

نویسندگان مقاله Z. Wang |
College of Power and Energy Engineering, Harbin Engineering University, Harbin, Heilongjiang ‎Province, 150001, China

Y. Yin |
College of Power and Energy Engineering, Harbin Engineering University, Harbin, Heilongjiang ‎Province, 150001, China

L. Yang |
DIME – Department of Mechanical, Energy, Management and Transportation Engineering, University of Genoa, Via Montallegro 1, 16145 Genova, Italy

L. Yan |
College of Power and Energy Engineering, Harbin Engineering University, Harbin, Heilongjiang ‎Province, 150001, China

Y. Luan |
College of Power and Energy Engineering, Harbin Engineering University, Harbin, Heilongjiang ‎Province, 150001, China


نشانی اینترنتی https://www.jafmonline.net/article_1182_941524dcbfaea63a94ec7e4f6452b88e.pdf
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات