این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 23 آذر 1404
Journal of Applied Fluid Mechanics
، جلد ۱۲، شماره ۴، صفحات ۱۳۰۳-۱۳۱۸
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Effect of Slot-Guidance and Slot-Area on Air Entrainment in a Conical Ejector Diffuser for Infrared Suppression
چکیده انگلیسی مقاله
A numerical study has been carried out on a new design of ejector diffuser (infrared suppression device). New design conceptualizes exploiting the shape of the slot openings. A circular arc is provided to guide the entrained fluid at the slot openings. Performance of guided-slot ejector diffuser (GED) has been compared with conventional (non-guided-slot) ejector diffuser (NGED) in terms of local and cumulative mass entrainment ratios, temperature distribution and static pressure recovery. Three slot-area variations are also studied, namely (i) increasing slot-area ranging 1 ≤ A0 ≤ 2.02, ( is area of 1st slot) (ii) constant slot-area A0 = 1 and (iii) decreasing slot-area ranging 0.49 ≤ A0 ≤ 1. Simulations have been carried out at fixed Reynolds number Re = 1.3 105. It is observed that GED has 3.5% higher cumulative mass entrainment ratio than NGED. GED forms cold annulus region below ejector diffuser wall from slot onwards which results in wall temperatures being close to ambient temperature (300 K). Higher mass entrainment rate and lower wall temperatures make GED a better infrared suppression device but static pressure recovery is better in NGED (Cp = 0.79) compared to GED (Cp = 0.43). Slot-area study reveals that the performance of increasing slot-area for GED and NGED is superior then constant and decreasing slot-area configurations. The cumulative mass entrainment is 20% higher while static pressure recovery is 45% more for the increasing slot-area GED when compared to the decreasing slot-area GED.
کلیدواژههای انگلیسی مقاله
Mass entrainment, Slot openings, Heat signatures, Static pressure recovery, Numerical study
نویسندگان مقاله
L. Singh |
Department of Applied Mechanics, Indian Institute of Technology Delhi, New Delhi, 110016, India
S. N. Singh |
Department of Applied Mechanics, Indian Institute of Technology Delhi, New Delhi, 110016, India
S. S. Sinha |
Department of Applied Mechanics, Indian Institute of Technology Delhi, New Delhi, 110016, India
نشانی اینترنتی
https://www.jafmonline.net/article_838_0705f096ed8fae97327fc84f8fd0a785.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات