این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 22 آذر 1404
Journal of Applied Fluid Mechanics
، جلد ۱۱، شماره ۲، صفحات ۴۸۳-۴۹۶
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Study of Effect of Flow Parameters on Base Pressure in a Suddenly Expanded Duct at Supersonic Mach Number Regimes using CFD and Design of Experiments
چکیده انگلیسی مقاله
Effectiveness of active control of micro jets has been examined by conducting experiments through an abruptly expanded axi-symmetric duct in a view to control base pressure. For this purpose, 1mm orifice diameter micro jets have been deployed at an interval of 900 along the exit diameter of the nozzle. The experiments have been conducted by considering three flow parameters at three levels. Mach number (M), length to diameter (L/D) ratio and area ratio (AR) are the three parameters used to conduct and analyze the flow experiments. Base pressure is considered to be the response variable. The experimentation has been carried out for two cases, i) without active control; ii) with active control. An L9 orthogonal array has been implemented to plan the experiments. It is observed that the control becomes effective for lower area ratios when compared to the higher ones. In addition to this, at high area ratios suction at the base decreases and hence base pressure continuous to diminish with increasing L/D until it reaches a value of L/D=6. The obtained experimental results are subjected to multiple linear regression analysis and Analysis of variance (ANOVA). The performances of the two linear regression models were tested for their prediction accuracy with the help of 15 random test cases. It is observed that, both linear regression models for base pressure without and with control are statistically adequate and capable of making accurate predictions. Furthermore, this work also concludes that, Mach number is the most significant factor affecting base pressure followed by area ratio and L/D ratio for both cases of experimentation. The obtained experimental results are further validated by CFD analysis and are found to be in good concurrence with each other.
کلیدواژههای انگلیسی مقاله
Base pressure, Mach number, Area ratio, Length to diameter ratio, Analysis of variance
نویسندگان مقاله
J. D. Quadros |
Department of Mechanical Engineering, Birla Institute of Technology, Off-shore campus, Ras Al Khaimah, UAE
S. A. Khan |
Department of Mechanical Engineering, International Islamic University Malaysia, Kuala Lampur, Malaysia
A. J. Antony |
Department of Mechanical Engineering, Bearys Institute of Technology, Mangalore, India
نشانی اینترنتی
https://www.jafmonline.net/article_609_b4351fc177124e1004c4b4a941785c7d.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات