این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 2 دی 1404
Journal of Dental Materials and Techniques
، جلد ۱۲، شماره ۴، صفحات ۱۷۵-۱۷۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Surface microhardness of nanohybrid and microhybrid composite resins light cured at different distances
چکیده انگلیسی مقاله
Objective: This study aimed to compare the surface microhardness of a nanohybrid and a microhybrid resin composite light-cured at two different distances.Methods: A total of 40 disc specimens were prepared for this in vitro experiment; 20 from a nanohybrid composite resin (Filtek P60; 3M ESPE) and 20 from a microhybrid composite resin (Filtek Z250; 3M ESPE). Each group was divided into two equal subgroups (n=10), based on the distance between the light-curing device and the composite surface (either 2 or 4 mm). After 24 hours of curing, the teeth underwent the microhardness test to determine the Vickers hardness number (VHN) at the surface. The data were subjected to statistical analysis using a two-way analysis of variance (ANOVA) at the significance level of P<0.05.Results: The nanohybrid resin composite showed higher microhardness values than the microhybrid resin at both 2 mm and 4 mm distances, although the difference between the two groups was only significant at the distance of 4 mm (P = 0.017). No significant difference was observed in the nanohybrid composite resin between the two curing distances (P = 0.151). However, the hardness of the microhybrid composite decreased significantly with increasing the curing distance from 2 to 4 mm (P = 0.015).Conclusions: This study reveals that light-curing distance significantly affects the microhardness of microhybrid composite resin. The nanohybrid composite showed comparable hardness up to the distance of 4 mm, indicating its suitability to be used in situations where a close curing distance cannot be achieved.
کلیدواژههای انگلیسی مقاله
Composite resins, Curing lights, Hardness test, Microhybrid composite, Nanohybrid composite, Restorative treatment
نویسندگان مقاله
| Zuloeta-Navarro Luz Clarita
Private Practice, Chiclayo, Peru.
| Orrego-Ferreyros Luis Alexander
Clinical Epidemiology Unit, School of Medicine, Cayetano Heredia University, Lima, Peru.
نشانی اینترنتی
https://jdmt.mums.ac.ir/article_23539.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات