این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 1 دی 1404
Iranian Journal of Medical Physics
، جلد ۲۰، شماره ۵، صفحات ۲۶۶-۲۷۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
CTV to PTV Margins Based On CBCT Method for Prostate Cancer of Patients Treated With VMAT Technique
چکیده انگلیسی مقاله
Introduction: Patient repositioning in treatment radiotherapy is one of the main factors that increase error of target irradiation. However additional margin is necessary to consider the uncertainties created along and around X, Y and Z-axis.Material and Methods: Set-up and random errors were calculated in translational and rotational axis for a sample of 20 prostatic patients; using daily IGRT-CBCT method. The aim of this study was to determine the additional margin that should be added from clinical target volume (CTV) to prevent toxicity and increase the irradiation precision in radiotherapy. The van Hark formula (PTV margin =2.5Σ +0.7σ) was used for all patients to perform PTV margin for prostatic localization.Results: The research performed for a sample of 20 consecutive patients. With respect to systematic error along the lateral axis, longitudinal and anterior-posterior was 2.32, 2.42 and 3.54 respectively. The Random error was 1.82, 2.19 and 1.76° along lateral axis, longitudinal and anterior-posterior respectively. The rotational systematic error was 1.49, 2.04 and 2.14° around lateral, longitudinal and anterior-posterior axis respectively. The Random error was 1.78, 1.75 and 1.63° around lateral, longitudinal and anterior-posterior axis respectively. The calculated safety margin to cover clinical target volume (CTV) taking the prostate variability into account measured 7.55, 8.08 and 10.79 mm for lateral, longitudinal and anterior posterior respectively and 7mm would be enough in the posterior side. Rotational set-up errors for almost 95% of patients were between -2° and 2°.Conclusion: The calculated safety margin in all direction was smaller than 1 cm except in anterior side that was 1 cm or more.
کلیدواژههای انگلیسی مقاله
CTV, PTV, CBCT method, VMAT, Prostate
نویسندگان مقاله
| Morad Erraoudi
Laboratory of high energy physics Modelisation Simulation, Faculty of Sciences, University Mohammed V, Rabat, Morocco
| Youssef Bouzekraoui
Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Sciences and Health Technologies, Settat, Morocco
| Hicham Asmi
Laboratory of high energy physics Modelisation Simulation, Faculty of Sciences, University Mohammed V, Rabat, Morocco
| FARIDA BENTAYEB
Departement of Physics, Laboratory of High Energy Physics, Modelling and Simulation, Faculty of Science, Mohammed V Agdal University, Rabat, Kingdom of Morocco
نشانی اینترنتی
https://ijmp.mums.ac.ir/article_20649.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات