این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
International Journal of Radiation Research، جلد ۲۲، شماره ۱، صفحات ۱۷-۲۲

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Evaluation of statistical prediction model fitting by combining fiducial markers and lung volume for stereotactic body radiotherapy
چکیده انگلیسی مقاله
Background: This study evaluates the tracking accuracy of the lung tumor volume and fiducial markers using four-dimensional computed tomography (4DCT) and fitted neural network models. Materials and Methods: This study utilized data from 31 patients (109 fiducial markers) who underwent stereotactic body radiotherapy (SBRT). The respiratory movements of fiducial markers, lung tumors, and lung volume were calculated using 4DCT. Cross-correlation coefficients were then calculated to analyze the phase movements of fiducial markers, lung tumors, lung volume, direction displacement, and lung area (upper, middle, and lower lobes). Statistical prediction models were used to evaluate the predictive accuracy of the left–right (LR), anterior–posterior (AP), cranial–caudal (CC), and three-dimensional (3D) cross-correlation coefficients between fiducial markers and lung tumors. The coefficient of determination (R2) was used to determine the accuracy of the statistical prediction models for the explanatory variables. Results: The correlation between fiducial marker and lung tumor, as well as lung tumor movement by time phase, yielded the following R2 values—LR: 0.920, AP: 0.319, CC: 0.675, and 3D: 0.449 for the upper lobe; LR: 0.567, AP: 0.627, CC: 0.955, and 3D: 0.939 for the middle/lower lobes. Statistically significant differences were observed in the CC and 3D directions within each lower lobe. Conclusions: The respiratory movements of fiducial markers and lung tumors in lung SBRT show stronger correlation with the movement of lung volume in the middle/lower lobes compared to that in the upper lobes. Combining a fiducial marker with lung volume improves the prediction accuracy of the respiratory movement of lung tumors.
کلیدواژه‌های انگلیسی مقاله Pelvis, Stereotactic body radiotherapy, Four-dimensional computed tomography, Respiratory movement, Statistical prediction model, lung cancer.

نویسندگان مقاله | Y. Tanabe
Faculty of Medicine, Graduate School of Health Sciences, Okayama University, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan


| T. Deguchi
Facility of Health Sciences, Okayama University Medical School, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan


| M. Kiritani
Facility of Health Sciences, Okayama University Medical School, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan


| N. Hira
Facility of Health Sciences, Okayama University Medical School, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan


| S. Tomimoto
Facility of Health Sciences, Okayama University Medical School, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan


| H. Nishikawa
Facility of Health Sciences, Okayama University Medical School, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan


| S. Tsumoto
Facility of Health Sciences, Okayama University Medical School, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan


| H. Tanaka
Department of Radiation Oncology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505, Japan



نشانی اینترنتی http://ijrr.com/browse.php?a_code=A-10-1-1132&slc_lang=en&sid=1
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده Radiation Biology
نوع مقاله منتشر شده تحقیق بدیع
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات