این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 26 آذر 1404
Analytical and Bioanalytical Electrochemistry
، جلد ۱۶، شماره ۱، صفحات ۲۳-۴۸
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Synthesis of TiO2@Multi-Walled Carbon Nanotube/Graphene Oxide Nanocomposite Electrode for Boosting Electrochemical Detection of Traces Azithromycin in Biological Samples
چکیده انگلیسی مقاله
Voltammetric detection of active substances has occupied an important place in the last decades. In this study, a novel highly efficient electrochemical sensor was fabricated using a combination of titanium dioxide nanoparticles and multi-walled carbon nanotubes mixed with graphene oxide sheets for the sensitive detection of the antibiotic Azithromycin. The results show that the constructed electrode has excellent electrocatalytic activity for Azithromycin detection (pH 7) compared to the unmodified electrode due to the mobilized TiO
2
nano-conductors on the MWCNTs@GO. The electrochemical behavior of Azithromycin was perfectly reversible. Transmission electron microscopy, X-ray diffraction, infrared spectroscopy, and Raman spectroscopy analyses were performed to examine the particularities of the IL-TiO
2
NPs@MWCNTs/GO/GCE interface. The effects of pH, accumulation time, scan rate, and the amount of multi-walled carbon nanotubes required for creation were investigated and optimized by applying Cyclic Voltammetry and DPV at pH 7.0. Phosphate buffer medium. The results showed that the number of protons and electrons involved in the electrooxidation reaction of Azithromycin is equal. The calibration curve was plotted in the concentration range of 10
-3
to 0.5×10
-6
M using the DPV method. The limit of detection and limit of quantification were calculated as 1.772×10
-8
M and 5.83×10
-8
M, respectively. The described method was applied to determine Azithromycin in pharmaceutical formulations and human blood and urine samples. The good recovery values between 96.6% and 99.1% suggest the applicability, efficiency, and reliability of the sensor for the determination of Azithromycin.
کلیدواژههای انگلیسی مقاله
Azithromycin, sensor, IL-TiO2 NPs@MWCNTs/GO/GCE, Human serum
نویسندگان مقاله
Jallal Zoubir |
Team of Catalysis and Environment, Ibn Zohr University, Faculty of Sciences, BP 8106, Agadir, Morocco
Ali Assabbane |
Team of Catalysis and Environment, Ibn Zohr University, Faculty of Sciences, BP 8106, Agadir, Morocco
Idriss Bakass |
Team of Catalysis and Environment, Ibn Zohr University, Faculty of Sciences, BP 8106, Agadir, Morocco
نشانی اینترنتی
https://www.abechem.com/article_710593_d9e55b889cdd05d430ea0a6dfd9dfab5.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات