این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 24 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۱۲، شماره ۳، صفحات ۲۱۱-۲۱۸
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Outcomes of Megaprosthesis Reconstruction for the Salvage of Failed Osteoarticular Allograft Around the Knee implanted before Skeletal Maturity in Primary Bone Sarcoma: A Case-Series
چکیده انگلیسی مقاله
Objectives: Functional expectations following the salvage of a failed osteoarticular allograft are poorly described. In this study, we aim to evaluate functional outcomes, implant survival, and complications of the megaprosthesis in salvaging a failed osteoarticular allograft around the knee.Methods: We retrospectively reviewed the medical profiles of 21 skeletally mature patients who underwent megaprosthesis reconstruction to salvage a failed osteoarticular allograft around the knee implanted before skeletal maturity. The location of reconstruction was the proximal tibia in 13 patients and the distal femur in eight patients. Knee function was evaluated by the Musculoskeletal Tumor Society (MSTS) score and the Toronto Extremity Salvage Score (TESS).Results: The mean age of patients was 16±1.7 years. The mean interval between the primary (allograft) and secondary (megaprosthesis) reconstructions was 59.4±23.6 months. At an average follow-up of 51.2 months, the mean knee range of motion was 101.2±15.6°. The mean MSTS score and TESS were 83.6±7 and 86.6±7.9, respectively. The mean limb length discrepancy was 2.5±1 cm before and 0.36±0.74 cm after the operation (P<0.001). Six postoperative complications (28.6%) occurred in this series, including one wound dehiscence, one periprosthetic fracture, two acute infections, one aseptic loosening, and one delayed periprosthetic infection. Only the last two complications required revision. Accordingly, the two- and five-year implant survivals were 95.7% and 90%, respectively.Conclusion: Megaprosthesis is a viable option for salvaging failed osteoarticular allografts around the knee. It also provides the opportunity to correct the limb length discrepancy. Level of evidence: IV
کلیدواژههای انگلیسی مقاله
Bone tumor, knee, oncologic prosthesis, Osteoarticular Allograft, salvage
نویسندگان مقاله
| Khodamorad Jamshidi
Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| Wael Ammar
Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| Khalil Kargar Shooroki
Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| Alireza Mirzaei
Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
نشانی اینترنتی
https://abjs.mums.ac.ir/article_23759.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات