این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 29 آذر 1404
Journal of Dental Materials and Techniques
، جلد ۱۳، شماره ۱، صفحات ۴۴-۵۱
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Three-dimensional accuracy of different techniques and materials for interocclusal bite registration
چکیده انگلیسی مقاله
Objective: This study aimed to compare the precision of a temporomandibular joint (TMJ)-related bite-registration technique with the occlusion-related registration technique using various polyvinyl siloxane materials. Methods: The interocclusal relation of 40 patients was transferred to stone casts by bite registrations using polyvinyl siloxane materials with different Shore harnesses (SH) values including Registrado clear (SH=70 A), Registrado xtra (SH=51 D) and Registrado scan (SH=90A). A joint-related registration technique (called the Gerber technique or gothic arch tracing) was also applied in all patents. The clinical contact situation and the contacts on stone casts were marked and transferred to a 3D-measuring software. The deviation of the occlusal contacts on the stone casts to the clinical reference was measured and compared between the registration methods. Results: There was no statistically significant difference in contact deviation values between different types of registration methods (P=0.093). However, the frequency of missing contacts was significantly greater in the Gerber technique compared to the occlusion-related bite registrations (P<0.001). Gerber technique revealed greater deviations of the contact points in subjects with pain in TMJ and masticatory muscles. Irrespective of the registration technique, the patient-related factors including orthodontic pretreatment, treatment of TMD with occlusal splints, pain on palpation, joint noises, and restricted mandibular movement did not significantly affect the degree of occlusal contact deviation (P>0.05).Conclusions: The hardness of the polyvinyl siloxane materials for occlusion-related bite registration did not affect the precision of the registration techniques in dentulous patients. Polyvinyl siloxane materials should be preferred for joint-related registration in TMD patients
کلیدواژههای انگلیسی مقاله
Bite registration, Gothic arch, hardness, occlusion, Polyvinyl Siloxane, Temporomandibular joint
نویسندگان مقاله
| Philipp-Cornelius Pott
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hanover, Germany.
| Carolin Becker
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hanover, Germany.
| Simone Schaumann
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hanover, Germany.
| Lara Bühnen
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hanover, Germany.
| Meike Stiesch
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hanover, Germany.
| Michael Eisenburger
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hanover, Germany.
نشانی اینترنتی
https://jdmt.mums.ac.ir/article_24050.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات