این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 18 آذر 1404
International Journal of Radiation Research
، جلد ۱۴، شماره ۴، صفحات ۳۱۳-۳۲۱
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
چکیده انگلیسی مقاله
Background: This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation. Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnrc Monte Carlo (MC) System was used for CT scanner simulation and DOSXYZnrc was used in order to produce patient specific phantom and irradiation of photons to phantom in step and shoot mode (axial mode). In order to calculate patient thorax organ dose, patient CT image of thorax as voxelized phantom was divided to a 64x64x20 matrix and 6.25 x 6.25 x 6.25 mm3 voxel size and this phantom was imported to DOSXYZnrc code. MC results in unit of Gy/particle were converted to absorbed dose in unit of mGy by a conversion factor (CF). We calculated patient thorax organ dose in MC simulation from all irradiated slices, in 120 kV and 80 kV photon energies. Results: Effective dose was obtained from organ dose and organ weighting factor. Esophagus and spinal cord received the lowest, and bone received the highest dose. In our study, effective dose in CT of thorax was 7.4 mSV and 1.8 mSv in 120 and 80 kV, respectively. Conclusion: The results of this study might be used to provide the actual patient organ dose in CT imaging and calculation of real effective dose based on organ dose.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
غلامرضا فلاح محمدی | gh r fallah mohammadi
department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
n ریاحی عالم | n riyahi alam
department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
gh گرایلی | gh. geraily
department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
r پایدار | r. paydar
radiation sciences department, faculty of allied medicine, iran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ایران (Iran university of medical sciences)
نشانی اینترنتی
http://ijrr.com/browse.php?a_code=A-10-1-634&slc_lang=en&sid=en
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/42/article-42-311159.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
مرور و بررسی کلی
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات