این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۳، شماره ۱، صفحات ۳۵-۴۴

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Quantitative Assessment of Conventional and Modern De-Noising on Nuclear Medicine Images
چکیده انگلیسی مقاله Introduction: One of the major problems in the development of nuclear medicine images is the presence of noise. The noise level in nuclear medicine images is usually reduced by the analysis of imaging data in a Fourier transform environment. The main drawback of this environment belongs to low signal to noise ratio in high frequencies because removing noise frequencies may remove data and times information as well. This problem becomes more serious when the most important signals are non-stationary. The aim of this research is to evaluate the effect of wavelet transform on nuclear medicine image. Materials and Methods: A brain phantom-like Hoffman phantom with 4 layers was used. Planar images were acquired from the phantom, with a total count of 107 (as reference image) and from each layer separately. The counts of planar images in each layer were increased from 100 to 700 kilo counts in seven steps. Different levels of white (Gaussian) noise was added to the reference images using MATLAB software. Simulation images using Simset software and NCAT phantom were also produced. Wavelet transform, Butterworth, Metz, Hanning(3*3) and Wiener filters were applied on all images. The Universal Image Quality Index (UIQI) was used to evaluate the image quality. Result: Wavelet transform can increase the value UIQI (UIQI = 0.7352). The effect of wavelet transform on the improvement of image quality is much better than Butterworth (UIQI = 0.3556) and Metz (UIQI = 0.3493) but almost the same as the effect of Wiener (UIQI = 0.7626) and Hanning (3*3) (UIQI = 0.8017). Discussion and Conclusion: Although wavelet transform is not the best method of reducing noise level, but its use can reduce the noise level like filters do. Assessment of commonly used thresholds as well as new design of a special threshold for wavelet transform in nuclear medicine images can improve the performance of this transform. 
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله sh علومی | sh. olumi
m.sc. in medical physics, tarbiat modarres university, tehran, iran

سازمان اصلی تایید شده: دانشگاه تربیت مدرس (Tarbiat modares university)

h رجبی | h. rajabi
assistant professor, medical physics dept., tarbiat modarres university, tehran, iran

سازمان اصلی تایید شده: دانشگاه تربیت مدرس (Tarbiat modares university)

سیدرضا زکوی | s r zakavi
associate professor, nuclear medicine dept., imam reza hospital, mashhad university of medical sciences, mashhad, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)

e حاجی زاده | e. hajizade
associate professor, biostatistics dept., tarbiat modarres university, tehran, iran

سازمان اصلی تایید شده: دانشگاه تربیت مدرس (Tarbiat modares university)

h غیاثی | h. ghiasi
m.sc. in medical physics, torfe hospital, tarbiat modarres university, tehran, iran

سازمان اصلی تایید شده: دانشگاه تربیت مدرس (Tarbiat modares university)


نشانی اینترنتی http://ijmp.mums.ac.ir/article_8129.html
فایل مقاله اشکال در دسترسی به فایل - ./files/site1/rds_journals/145/article-145-314847.pdf
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات