این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 23 آذر 1404
Middle East Journal of Cancer
، جلد ۱۵، شماره ۳، صفحات ۲۱۷-۲۲۵
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Lifetime Attributable Risk of Breast Cancer Incidence in Brain CT Scans
چکیده انگلیسی مقاله
Background:
The breast, being a highly radiosensitive organ, is exposed to scattered radiation during brain computed tomography (CT) scans. This study aims to estimate the lifetime attributable risk (LAR) of female breast cancer resulting from brain CT scans.
Method:
90 women participated in this cross-sectional study. The LAR of breast cancer incidence was estimated based on health risks associated with exposure to low levels of ionizing radiation, as per the BEIR VII Phase 2 guidelines. The absorbed dose to the breasts was measured using thermoluminescence dosimeters, and the effective dose was calculated from the dose length product. All brain CT scans were conducted using a 16-slice scanner (SOMATOM EMOTION). Statistical analysis involved the Mann-Whitney test to compare the means of breast dose, effective dose, and LAR at a significance level of 0.05.
Results:
The mean age of the participants was 40 ± 22 years, with an age range of 10 to 83 years. The average dose to the breasts without and with shielding was 0.26 ± 0.19 mGy and 0.096 ± 0.13 mGy, respectively (
P
< 0.05). The effective dose was 0.85 ± 0.35 mSv without shielding and 0.79 ± 0.32 mSv with shielding (
P
= 0.539). The maximum LAR was 5.41 cases per 100,000 persons aged 10-15 years without shielding. The average LARs were 1.16 and 0.41 breast cancer incidences per 100,000 persons with and without shielding, respectively (
P
< 0.05).
Conclusion:
The LAR of breast cancer in brain CT scans is significant and should not be overlooked. The use of breast shielding can substantially reduce this risk. Therefore, it is recommended to employ radioprotective shields to cover the breasts during this type of scan.
کلیدواژههای انگلیسی مقاله
Breast neoplasms, Tomography, X-Ray computed, Radiation protection
نویسندگان مقاله
Salman Jafari |
Department of Radiology Technology, School of Paramedicine, Hamadan University of Medical Sciences, Hamadan, Iran
Abbas Alikarami |
Department of Nuclear Physics, Bu-Ali Sina University, Hamadan, Iran
Kaveh Faraji |
Department of Radiology Technology, School of Paramedicine, Hamadan University of Medical Sciences, Hamadan, Iran
Soheib Rezaie |
Department of Radiology Technology, School of Paramedicine, Hamadan University of Medical Sciences, Hamadan, Iran
Karim Ghazikhanlou Sani |
Department of Radiology Technology, School of Paramedicine, Hamadan University of Medical Sciences, Hamadan, Iran
نشانی اینترنتی
https://mejc.sums.ac.ir/article_49679_19d4fc42adcfcc43528a66cd147a8d79.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات