این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 26 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۱۲، شماره ۸، صفحات ۵۷۴-۵۷۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Percutaneous Sacroiliac Screw Fixation: A Modified Screw Insertion Method Using Just 2 Fluoroscopy Views
چکیده انگلیسی مقاله
Objectives: Percutaneous sacroiliac screw fixation (PSSF) is a well-defined method of surgery to fix unstable fractures of the pelvic ring with fewer post-surgical complications. However, the complex anatomy of the mentioned area makes PSSF a formidable challenge. The present study aimed to investigate a modified screw insertion method using two views of fluoroscopy X-ray instead of the prior three views to reduce the duration of operations and radiation exposures.Methods: The present study was performed on 10 radiopaque plastic pelvic models (including 20 half pelvis) during simulated surgical procedures. Of the 20 screws, 10 were inserted using the conventional method with the navigation of three fluoroscopy views (Group A). The remaining 10 were inserted using the modified method with the navigation of two fluoroscopy views, including just the outlet and inlet views, without taking the lateral view, based on our theory and order of fluoroscopy (Group B). Following screw insertion, the accuracy of screw locations was evaluated using a computed tomography (CT) scan, and the duration of operations and radiation exposures were compared between the two surgery methods at the end of the study.Results: In both groups, nine screws (90%) were located correctly, and one screw (10%) perforated the anterior wall of the first sacral vertebra. The mean±SD of the duration of radiation exposure in groups A and B was 6.1±1.0 min and 4.2±0.1 min, respectively (P=0.01). Moreover, the mean±SD of operation duration in group A was 45.7±5.8 min, but this value in group B was 35.5±4.5, which showed a significant decrease in operation duration (P=0.04).).Conclusion: PSSF using a modified screw insertion method with just two fluoroscopy views not only had similar accuracy to conventional methods but also could decrease operation time and the following radiation exposure. Level of evidence: IV
کلیدواژههای انگلیسی مقاله
Fluoroscopy, Pelvic imaging navigation, Percutaneous screw insertion, Sacroiliac joint
نویسندگان مقاله
| Farshid Dehkhoda
Department of Orthopedics, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| Alireza Manafi Rasi
Department of Orthopedics, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| Reza Zandi
Department of Orthopedics, Taleghani Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| Maryam Abedi
Department of Pathology, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
| Seyed Shayan Ebadi
Department of Orthopedics, Shahid Beheshti University of Medical Sciences, Tehran, Iran
نشانی اینترنتی
https://abjs.mums.ac.ir/article_24585.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات