این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۲۱، شماره ۳، صفحات ۱۶۸-۱۷۵

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Performance of different Strength of Aperture Shape Controller on VMAT technique for Head and Neck, Pelvis, and Breast Cancer using Halcyon Machine
چکیده انگلیسی مقاله Introduction: Before starting optimization using the Volumetric Modulated Arc Therapy (VMAT) technique, the choice of the convenient aperture shape controller can be one of the most important factors that affect the plan quality.Material and Methods: Three different clinical cases were selected: head and neck cancer, pelvic cancer (prostate, cervix, and endometrium), and breast cancer treated with the VMAT technique. By keeping the same conditions, plans were reoptimized by varying aperture shape controllers (OFF, VERY LOW, LOW, MODERATE, HIGH, VERY HIGH). For plans evaluation, the homogeneity index (HI), conformity index (CI), target coverage (D98% and V98%), dose max (DMAX) and near max (D2%), treatment time delivery (MUs), and gamma index passing rate were analyzed.Results: All the studied localizations treated with the VMAT technique met clinical objectives. The VERY LOW technique achieved the best dose conformity for all localizations. A slight improvement in terms of PTV coverage and max dose is obtained in a VERY LOW technique for pelvic cancer. For breast cancer, almost the same results were obtained. However, for head and neck treatments, better results were observed with the HIGH and VERY HIGH techniques, where coverage and maximum dose improved by up to 6%.Conclusion: Changing the Strength of Aperture Shape Controller in VMAT optimization can affect dose calculation, especially in concave volumes such as Head and Neck.
کلیدواژه‌های انگلیسی مقاله Target Coverage, Leaf Sequencing, Cancer, Beamlets, VMAT technique, Aperture Shape Controller, optimization

نویسندگان مقاله | Morad Erraoudi
Faculty of Sciences, LPHE-M&S, Mohammed V University, Rabat, Morocco


| Youssef Bouzekraoui
Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Sciences and Health Technologies, Settat, Morocco


| Mohammed Yassine Herrassi
Private Hospital Casablanca-AKDITAL, Morocco


| Khalid Elouardi
Department of physics, University of Mohammed 1st, Oujda, Morocco


| Yassir Raoui
Faculty of Sciences, LPHE-M&S, Mohammed V University, Rabat, Morocco


| Mohamed El ghalmi
Faculty of Sciences, LPHE-M&S, Mohammed V University, Rabat, Morocco


| FARIDA BENTAYEB
Departement of Physics, Laboratory of High Energy Physics, Modelling and Simulation, Faculty of Science, Mohammed V Agdal University, Rabat, Kingdom of Morocco



نشانی اینترنتی https://ijmp.mums.ac.ir/article_22136.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات