این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
Iranian Journal of Otorhinolaryngology
، جلد ۳۶، شماره ۵، صفحات ۶۰۳-۶۱۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Performance of Wrist-Worn Pulse Oximeter for the Screening of Obstructive Sleep Apnea
چکیده انگلیسی مقاله
Introduction:A sleep apnea monitor (BM2000A) is a wrist-worn device that measures oxygen saturation and pulse rate during sleep. This study aimed to evaluate the efficacy of the watch-like BM2000A for screening obstructive sleep apnea (OSA).BM2000A; Home sleep apnea testing; Obstructive sleep apnea; Polysomnography; Wrist pulse oximeter Materials and Methods:102 patients complaining of sleep breathing disorders were included; 81% were men and 19% were women. All participants underwent overnight simultaneous polysomnography (PSG) and BM2000A sleep monitoring. The number of apneas and hypopneas, apnea-hypopnea index (AHI), percentage of time spent with oxygen saturation under 90%, average oxygen saturation, lowest oxygen saturation, and duration of sleep were computed by the BM2000A and PSG. Then, these parameters were compared to validate the BM2000A.Results:All parameters, measured with BM2000A, had a good correlation (r ≥ 0.6, p < 0.0001) with PSG-derived indexes, except for sleep time (r = 0.19, p = 0.061) and hypopnea index (r = 0.4, p < 0.0001). AHI had the strongest correlation (r = 0.87, p < 0.0001). The mean difference between AHI values calculated with PSG and wrist-worn pulse oximeter (WPO) was -17.66 events/h (95% CI: -50.39 to 15.06). In AHI ≥ 5, BM2000A had 90.7% sensitivity, 100% specificity, 91.2% accuracy, and 0.994 area under the curve. Using AHI ≥ 5, ≥ 15, and ≥30 as the screening criteria, optimal WPO-AHI cutoffs to improve the screening accuracy were 3.10, 8.92, and 13.05.Conclusions:BM2000A-derived results properly correlate with PSG and can provide OSA screening with good sensitivity and specificity.
کلیدواژههای انگلیسی مقاله
BM2000A, Home sleep apnea testing, Obstructive Sleep Apnea, Polysomnography, Wrist pulse oximeter
نویسندگان مقاله
| Sama Jabbaripour
Medical Student, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
| Sareh Saien
Medical Student, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
| Reihaneh Heidari
Otolaryngology Research Center, Vali Asr Hospital, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran.
| Reza Erfanian
Otolaryngology Research Center, AmirAlam Hospital, Tehran University of Medical Sciences, Tehran, Iran.
| Amin Amali
Otolaryngology Research Center, Vali Asr Hospital, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran.
نشانی اینترنتی
https://ijorl.mums.ac.ir/article_24807.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات