چکیده انگلیسی مقاله
Background: Boron neutron capture therapy (BNCT) is a radiotherapy that combines biological targeting and high linear energy transfer. A potential therapeutic approach for non-small cell lung cancer (NSCLC) is considered. However, dose in lung tumor is not homogeneous, and it will reduce the effect of BNCT treatment. In order to improve the dose distribution of BNCT, the multi-field irradiation strategy and its effects need to be explored. Materials and Methods: Common NSCLC model was defined in Chinese hybrid reference phantom and the boron concentration in skin and tumor varied from 6 to 18 ppm and from 30 to 65 ppm, respectively. Monte Carlo method for dose distribution calculation was used. Accelerator-based neutron source called “Neuboron source” was used and multi-field source irradiation plans were designed to optimize the dose distribution. Results: Under one-field irradiation, it was not feasible to perform BNCT, because the skin dose is unlikely to meet its dose limit. Under two- and three-field irradiation, the uniformity of tumor dose was improved and the maximum dose to organs at risk (OARs) decreased. If boron concentration in skin was between 6-18 ppm, BNCT was feasible with the boron concentration in tumor reaching about 57-60 ppm for two-field irradiation and 41-45 ppm for three-field irradiation, respectively. Conclusion: The multi-field irradiation plan could improve the dose distribution and the feasibility of BNCT for NSCLC. Theoretical distributions of Boron-10 were obtained to meet the treatable requirement of BNCT, which could provide a reference for NSCLC using BNCT in future multiple-field irradiation.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| x. tang
department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china
| x. tang
department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china
d shu | d. shu
department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china
c geng | c. geng
department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china
c gong | c. gong
department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china
s hang | s. hang
department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china
d chen | d. chen
department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china
نشانی اینترنتی
http://ijrr.com/browse.php?a_code=A-10-1-644&slc_lang=en&sid=en
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/42/article-42-326529.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
مرور و بررسی کلی
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات