این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 3 دی 1404
Iranian Journal of Medical Physics
، جلد ۲۱، شماره ۴، صفحات ۲۵۸-۲۶۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Influence of Segment Shape Optimization Parameter in Radiotherapy Volumetric Modulated Arc Therapy Planning of Cervical Cancer
چکیده انگلیسی مقاله
Introduction: The aim of this study is to find out the influence of different Segment shape optimization (SSO) parameters in radiotherapy Volumetric Modulated Arc therapy (VMAT) planning of Cervical Cancer and to find out the optimized value for cervical cancer patients.Material and Methods: It was a retrospective study of 20 Ca cervix patients. Every patient had six plans named SL1, SL5, SL10, SL15, SL20, and NSL. In each case, the value of the shaping loop will be changed during the VMAT plan, while the other optimization parameters and constraint functions will remain the same in each case. All Dosimetric parameters have been measured and analysed for Planning Target Volume (PTV) and Organ at risk (OAR) dose, Monitor Unit (MU), memory, Plan Delivery Time (PDT), and Gamma Passing Rate (GPR) for comparison purposes.Results: In NSL cases, the PTV dose derived from the DVH did not meet the clinical standards D95% = 86.8% (<95%) with a poorer homogeneity index (HI = 0.2). As the SL value increases, plan quality increases, monitor units increase slightly and plan delivery time decreases while there is a parallel increase in memory consumption. There is no statistical difference in target dose and OAR dose between the SL5 and SL1 plans (P > 0.05) compared with the other groups. SL5 has the least plan memory compared to other SL values.Conclusion: Based on the plan quality, the dose accuracy, and the efficiency of delivery, SL1 and SL5 have similar characteristics in cervical cancer cases. Both SL1 and SL5 values should recommend for cervical cancer VMAT planning.
کلیدواژههای انگلیسی مقاله
Cervical Cancer, VMAT, sequencing parameter, volumetric modulated arc therapy
نویسندگان مقاله
| Nidhi Jain
Department of Physics, AIAS, Amity University, U.P., India
| Alok Kumar
Department of Radiation Oncology, Netaji Subhas Chandra Bose Cancer Hospital and Institute, Kolkata, West Bengal, India
| Ashok Kumar
Department of Physics, AIAS, Amity University, U.P., India
نشانی اینترنتی
https://ijmp.mums.ac.ir/article_25065.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات