این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۲۱، شماره ۴، صفحات ۲۶۵-۲۷۱

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Absorbed Dose Measurements for Teletheraphy Prediction of Superficial Dose Using Halcyon Linear Accelerator
چکیده انگلیسی مقاله Introduction: Measurement of entrance dose and dose at different depth is essential to avoid over dose and under dose of patients. The aim of this study is to verify the variation in the absorbed dose using a water equivalent material.Material and Methods: The plastic phantom was arranged on the couch of the halcyon linear accelerator by Varian with the farmer ionization chamber inserted and connected to the electrometer. The image of the setup was taken using the High-Quality Single 1280x1280x16 higher on the service mode, to check the alignment with the isocenter. The beam quality TPR20,10 (Tissue phantom ratio) was done to check the beam quality of the machine at a field size of 10 cm x 10 cm.  The calibration was done using SAD type set-up at a depth of 5 cm. This process was repeated for ten consecutive weeks and the values recorded.Results: The results of the beam output for the teletherapy machine were satisfactory and accepted in comparison with the commissioned measurement of 0.62. The beam quality TPR20,10 (Tissue phantom ratio) was reasonable with respect to the beam quality of the machine at a field size of 10 cm x 10 cm.Conclusion: The results of the beam quality and the absorbed dose rate showed a good consistency over the period of ten weeks with the commissioned measurement value.
کلیدواژه‌های انگلیسی مقاله Linear Accelerator Multi, Leaf Collimator Volumetric Modulated Arc Therapy Drum Phantom

نویسندگان مقاله | Raymond Njinga
Department of Physics, University of Medical Sciences Ondo, Ondo State, Nigeria


| Adeneye Samuel
Department of Radio Biology, Radio Diagnosis and Radiotherapy, College of Medicine University of Lagos/NSIA-LUTH Cancer Centre: Idiaraba, Lagos, Nigeria


| Akinyode Ajimo
Department of Physics, University of Medical Sciences Ondo, Ondo State, Nigeria


| Christopher Olowookere
Department of Physics, University of Medical Sciences Ondo, Ondo State, Nigeria



نشانی اینترنتی https://ijmp.mums.ac.ir/article_25066.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات