Experimental Study of Pulsatile Electric Field Effect on a Single Drop Rupture Through the Response Surface Methodology: Critical Electric Field Estimation
چکیده انگلیسی مقاله
Electro-coalescence has been an environmentally friendly technology for decades. However, electric field strength should not exceed a critical value (E
crit
) to inhibit droplets from disintegrating during coalescence. Response surface methodology (RSM) with a D-optimal design was utilized to develop a model to achieve the maximum E
crit
of a single drop. The p-values showed that all studied variables were statistically significant, including Waveform, frequency, drop diameter, and interfacial tension. The results showed that by increasing the drop diameter,
decreases at all frequencies in the presence and absence of surfactant. Frequency change revealed E
crit
increases with a moderate slope for all waveforms. Because the change
in field periodicity at higher frequencies becomes more frequent, this observation was attributed to a lower degree of drop deformation due to shorter on-time intervals of pulsatile electric field and non-compliance
of drop vibration with field frequency. Moreover, the critical electric field declined by decreasing the interfacial
tension for all waveforms and the entire frequency range examined. Adding SDS surfactant diminishes the force of surface tension against electric force and the critical field is reduced accordingly. Following the revelation of the interaction between diameter and frequency, elevated frequencies significantly impact larger droplets, and the sensitivity of E
crit
to the diameter decreases with frequency. This suggests higher frequencies as a valuable and fast controllable variable to compensate for the effect of droplet size distribution. Optimization suggested a minimum drop diameter and a maximum frequency that can be used
as two essential limits for the robust electro-coalescer design. The maximum critical electric field was obtained
for Pulse 90 at a frequency of 1000 Hz for a drop diameter of 2.12 mm in the absence of the surfactant.
These findings can be used to attain the appropriate ranges of variables to design a robust electro-coalescer.
کلیدواژههای انگلیسی مقاله
Response surface methodology,Critical electric field,Frequency,Interfacial tension,Waveform
نویسندگان مقاله
Zahra Shahmoradi |
Separation Processes & Nanotechnology Lab. Caspian Faculty of Engineering, College of Engineering, University of Tehran, Rezvanshahr, I.R. IRAN
Seyed Hamed Mousavi |
Separation Processes & Nanotechnology Lab. Caspian Faculty of Engineering, College of Engineering, University of Tehran, Rezvanshahr, I.R. IRAN
نشانی اینترنتی
https://ijcce.ac.ir/article_715025_d68144bb316a0a59c0ce0c24e0a55fb6.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات