این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 1 دی 1404
Journal of Dental Materials and Techniques
، جلد ۱۳، شماره ۴، صفحات ۲۰۱-۲۰۶
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparations
چکیده انگلیسی مقاله
Objective: This study compared the dimensional accuracy of two polyvinyl siloxane putty-wash impression techniques with the digital impression method for single implants adjacent to tooth crown preparations.Methods: Impressions were taken from a dental arch containing a full-metal preparation on the first molar adjacent to a Straumann tissue-level implant at the second premolar site. A laboratory scanner generated a standard tessellation language (STL) file as the reference for comparisons. Three methods were tested, each performed 10 times: (1) one-step putty-wash technique, (2) two-step putty-wash technique, and (3) digital impressions. Dimensional accuracy was assessed by measuring overall die dimensions, die height, die width, and the tooth-implant distance, using Geomagic Wrap software. Statistical analyses included one-way ANOVA and the Kruskal-Wallis test, with significance at P < 0.05.Results: No significant differences were found among the methods for the die height (P = 0.130), die width (P = 0.180), and tooth-implant distance (P = 0.486). However, the digital impression method showed significantly greater overall dimensional accuracy than the one-step putty-wash technique (P = 0.004). The two-step putty-wash method showed no significant difference with the one-step method or digital impressions concerning the overall die accuracy (P > 0.05).Conclusions: Digital impressions demonstrated significantly higher overall dimensional accuracy than the one-step putty-wash technique. Die height, die width, and tooth-implant distance were comparable across methods. Digital impressions are recommended for optimal accuracy when taking impressions from single implants adjacent to tooth crown preparations. The two-step putty-wash method offers a reliable alternative when digital tools are unavailable.
کلیدواژههای انگلیسی مقاله
Dental Impression Technique, Dental impression material, Vinyl polysiloxane, dental prosthesis, Dental implants, Dimensional Measurement Accuracy
نویسندگان مقاله
| Hamidreza Rajati Haghi
Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
| Hossein Dashti
Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
| Saeid Sabzevari
Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
| Amineh Khoshbakhti
Student Research Committee, Mashhad University of Medical Sciences, Mashhad, Iran
| Alireza Dankoub
Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
نشانی اینترنتی
https://jdmt.mums.ac.ir/article_25380.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات