چکیده انگلیسی مقاله Objectives: The purpose of this study is to evaluate the outcomes of a polyaxial locking plate utilizing locking-cap fixation for treatment of patients with displaced olecranon fractures. Methods: A retrospective review was performed for all consecutive patients at two institutions with displaced olecranon fractures treated with a polyaxial locking plate. Patients were required to have at least 1-year follow up. Clinical outcomes including the Disabilities of the Arm, Shoulder, and Hand (DASH) score, Single Assessment Numeric Evaluation (SANE), along with a Likert-scaled satisfaction survey ranging between 1-5 (1= very unsatisfied and 5= very satisfied) were collected. Results: The plate osteosynthesis was performed on 24 patients with displaced olecranon fractures. Functional outcome scores were collected on 19 (79.2%) patients. The mean age at the time of surgery was 57.9 years (range, 23 to 78) and mean clinical follow-up was 21.0 ± 6.6 months (range, 12-34 months). All patients achieved osseous :union: in an acceptable position. Four (16.7%) patients complained of plate related pain and 6 (25%) patients complained of postoperative stiffness. Complications were found in 3 (12.5 %) patients, which included two neuropathies and one hardware failure in which a patient presented following a fall with a broken screw. No patients required revision surgery nor removal of hardware. A total of 16 (84%) patients were somewhat to very satisfied. The mean SANE score was 87.8 ± 14.6 (range: 45-100) and the mean DASH score was 13.8 + 17.5 (range: 0-55.8). Seventeen (89%) patients rated their elbows as 75% or better on SANE assessment and 16 (84%) patients achieved DASH scores of less than 30. Conclusion: Polyaxial plate fixation utilizing locking-cap technology resulted in excellent short-term functional outcomes in patients with displaced olecranon fractures. Further follow-up is needed to determine the long-term outcomes of locking-cap constructs for olecranon fractures.         Level of evidence: IV
کلیدواژه‌های انگلیسی مقاله clinical outcomes, Elbow Fractures, Elbow surgery, Locking Cap, Locking Plate, Mayo Classification, Olecranon fracture, Polyaxial

نویسندگان مقاله | Michael Gutman
Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA


| Manan Patel
Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA


| James Connelly
Brown University, East Providence, Rhode Island, USA


| Edward Paxton
Brown University, East Providence, Rhode Island, USA


| Surena Namdari
Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA


| John Horneff
Clinical Orthopaedic Surgery, Shoulder & Elbow Division, University of Pennsylvania, Philadelphia, Pennsylvania, USA



نشانی اینترنتی https://abjs.mums.ac.ir/article_25004.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده RESEARCH PAPER
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات