Pulmonary Valve Replacement Using an Intraoperatively Created Trileaflet Autologous Pericardial Valve: A Case Series
چکیده انگلیسی مقاله
Background: Pulmonary valve replacement is inevitable for the majority of patients with long-standing pulmonary regurgitation. The purpose of this study was to describe the experience of employing a novel technique to create an intraoperatively handmade trileaflet pulmonary valve with glutaraldehyde-treated autologous pericardium (the AAA valve).
Methods: This case series study was conducted from September 2018 to March 2021 at Shiraz University of Medical Sciences, Shiraz, Iran. The surgical technique involved harvesting and treating with glutaraldehyde of the pericardium, constructing a trileaflet valve by encapsulating the pericardium within a Dacron tube with a diameter of 22 mm and a length of 20 mm, and implanting it into the pulmonary valve position.
Results: The AAA valve was constructed for 10 patients with a mean age of 16.20±5.81 years, seven of whom had undergone surgery for tetralogy of Fallot. The patients’ mean follow-up length was 32.30±13.64 months. The AAA valve regurgitation was none to moderate. At the time of follow-up, all patients had AAA valve stenosis that was less than moderate, except for one case. Cardiac magnetic resonance imaging and echocardiography results confirmed mild leaflet motion restriction in the patient with moderate stenosis. The anatomic valve parameters in MRI revealed a mean geometric height, coaptation height, and effective height of 20.23±2.40 mm, 10.42±1.67 mm, and 14.34±2.24 mm, respectively. One patient died from non-cardiac causes.
Conclusion: The surgical establishment of a native pericardial valve in the pulmonary valve position yielded satisfactory short-term to midterm results and might be considered a viable alternative to the available options.
کلیدواژههای انگلیسی مقاله
Pericardium,Autografts,Pulmonary valve insufficiency,Glutaraldehyde
نویسندگان مقاله
Ahmad Ali Amirghofran |
Department of Cardiac Surgery, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
Kamran Jamshidi |
Department of Cardiac Surgery, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
Mohammadreza Edraki |
Department of Pediatrics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
Gholamhossein Ajami |
Department of Pediatrics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
Hamid Amoozgar |
Department of Pediatrics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
Mohammadreza Sabri |
Department of Pediatrics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
Hamid Arabi |
Department of Cardiac Surgery, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
Elahe Nirooie |
Department of Cardiac Surgery, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
Mohammad Kasaie |
Department of Cardiac Surgery, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
Rahim Hemmati |
Department of Cardiac Surgery, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
Mina Amiri |
Department of Cardiac Surgery, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran