این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 23 آذر 1404
Journal of Applied Fluid Mechanics
، جلد ۱۸، شماره ۵، صفحات ۱۱۸۹-۱۲۰۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Numerical Analysis of the Inlet and Outlet Diameter Effects on Pulsation Dynamics and Cavitation in the Lobe Pump
چکیده انگلیسی مقاله
To investigate the impact of inlet and outlet diameters on the performance of lobe pumps, this paper analyses six lobe pumps with an inlet and outlet diameter ratio of 1, as well as five lobe pumps with varying inlet and outlet diameter ratios, while keeping other conditions constant. Three-dimensional unsteady numerical simulations of the pumps were conducted using the full cavitation model and the re-normalization group (RNG) k-ε turbulence model. The results show that for the lobe pumps with internal diameters between 40 mm and 100 mm, the shaft power is reduced by 17.6%, the pressure is reduced by 0.4 MPa, the pulsation coefficient is reduced by 18%, the variation of the gas volume fraction at the gap is in the range of 0.2 to 0.8, and the maximum value of the radial force in the X-direction decreases from 58.36 to 17.6 kN, and that the maximum value of the radial force in the Y-direction decreases from 14.56 to 3.25 kN. When the scale is increased from 0.6 to 1, the shaft power decreases by 25.9%, the pressure decreases by 0.1 MPa, the pulsation coefficient decreases by 6%, the volume fraction of gas at the gap varies between 0.1 and 0.8, and the maximum radial force in the X-direction decreases from 17.63 to 12.52 kN, and in the Y-direction decreases from 7.68 to 6.32 kN. This shows that choosing a suitable inner diameter can reduce the cavitation tendency of the lobe pump, enhance its anti-cavitation ability, optimize the fluid flow characteristics, and thus improve its reliability and stability.
کلیدواژههای انگلیسی مقاله
Lobe pumps,Inlet diameter,Outlet diameter,Cavitation,Shaft power,Pressure pulsation,Dynamic grid technique
نویسندگان مقاله
H. Zhou |
College of Metrology Measurement and Instrument, China Jiliang University, Hangzhou, 310018, China
P. Zhou |
College of Metrology Measurement and Instrument, China Jiliang University, Hangzhou, 310018, China
L. Meng |
Key Laboratory of River Basin Digital Twinning of Ministry of Water Resources, Beijing, 310018, China
C. Xiang |
School of Mechanical Engineering, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China
C. Xiang |
School of Mechanical Engineering, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China
H. Qian |
School of Mechanical Engineering, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China
نشانی اینترنتی
https://www.jafmonline.net/article_2625_e84ab384ba1f37effc89939ca11ceded.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات