این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۲۱، شماره ۶، صفحات ۳۵۵-۳۶۴

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Comparison of Methods of µ-Map Generation: MR-Based Method in PET/MR Imaging Versus Pseudo-CT Method in Radiotherapy Dose Planning
چکیده انگلیسی مقاله Introduction: Attenuation correction is essential for accurate PET imaging and radiotherapy (RT) dose planning. However, PET/MR systems face a significant challenge due to the lack of direct attenuation data from MR images, unlike PET/CT where CT provides inherent attenuation information. Similarly, the increasing use of MRI in RT planning necessitates pseudo-CT methods for accurate dose calculation. This study compares MR-based µ-map generation for PET/MR and pseudo-CT methods for RT planning, addressing their challenges and limitations to improve treatment accuracy and patient care. Material and Methods: The study involved patient selection, image processing, and generation of MR-based attenuation maps (µ-maps) for PET attenuation correction and pseudo-CTs for RT dose planning using advanced computational software. Results: MR-based µ-maps, potentially useful for PET attenuation correction, and pseudo CTs, potentially applicable in radiotherapy planning, were successfully generated. Head images showed MR-based µ-maps overestimating bone for two patients (deviations of 4.0% and 4.2%). Both MR-based and CT µ-maps exhibited dynamic and continuous µ-values for head bone. In the pelvis, pseudo-CT underestimated bone volume in five patients (deviations of 18.7%, 21.3%, 9.6%, 14%, and 10%). Pseudo-CT's bone µ-values lacked continuity compared to CT µ-maps. Pelvis studies revealed more dynamic and broader µ-value range for muscle in CT µ-maps than pseudo-CT and MRI µ-map. Conclusion: These findings suggest the need for careful consideration and validation of attenuation correction methods, especially in regions with complex anatomical structures, to ensure accurate treatment delivery and enhance patient care in the context of PET/MR and radiotherapy.
کلیدواژه‌های انگلیسی مقاله Magnetic Resonance Imaging (MRI) Computed Tomography (CT) Positron, Emission tomography (PET) Radiotherapy

نویسندگان مقاله | Isaac Kwesi Acquah
University of Education, Winneba, Ghana


| Stephen Inkoom
University of Ghana, School of Nuclear and Allied Health Science, Ghana


| Francis Hasford
Ghana Atomic Energy Commission, Ghana



نشانی اینترنتی https://ijmp.mums.ac.ir/article_24253.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات