این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 24 آذر 1404
Analytical and Bioanalytical Electrochemistry
، جلد ۱۷، شماره ۳، صفحات ۲۰۴-۲۱۶
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Electrochemical Detection of Catechol using Synthesized Titanium Oxide Nanoparticles
چکیده انگلیسی مقاله
The fabrication of advanced electrodes has garnered significant attention due to their exceptional sensitivity and selectivity for detecting catechol samples. Titanium dioxide nanoparticles (TiO₂ NPs) have emerged as highly effective modifiers for carbon paste electrodes (CPEs), attributed to their unique electrochemical characteristics and enhanced conductivity. In this study, TiO₂ NPs are prepared via the combustion method (CM), offering a reliable strategy for boosting electrode performance. This work aims to synthesize the TiO
2
NPs by using Titanium (III) sulfate as precursor materials, and citric acid as fuel to get the desired TiO
2
NPs. The confirmation of NPs is done through various techniques such as field emission scanning microscopy (FESEM), microstructure analysis by XRD, elemental composition by EDS, and absorption vibration levels by Raman spectroscopy. TiO
2
NPs are used for the development of electrode applications to determine catechol (CC) using carbon paste electrodes (CPE). The electrode surface is modified into a TiO
2
composite carbon paste electrode (TiCCPE). The electrochemical techniques are performed using a phosphate buffer solution (BS) of 0.1 M at a pH range of 7.0 of a two-electron transfer system with scan rates variation from 0.50-0.400 V/s signifies reaction of absorption-controlled process, and concentration studies from 0.2 µM to 1.6 µM with detection and quantification limit of 0.21 µM and 0.71 µM and was found using Linear sweep voltammetry technique (LSV). The electrode modification associated with synthesized TiO
2
NPs assists in an outstanding way to sense the CC, as good sensitivity, stability, selectivity, and reproducibility of catechol detection were assessed using electrochemical techniques throughout the studies.
کلیدواژههای انگلیسی مقاله
TiO2 NPs,XRD,linear sweep voltammetry,Catechol,Modified electrode,Detection limit
نویسندگان مقاله
Ramesh S. Bhat |
Chemistry, NMAM Institute of Technology, Nitte-574110
Adigerhalli G. Bindu |
Department of Chemistry, NMAM Institute of Technology, NITTE (Deemed to be University), Nitte-574110, India
Shivani Shivani |
Department of Chemistry, NMAM Institute of Technology, NITTE (Deemed to be University), Nitte-574110, India
Ampar C. Hegde |
Electrochemistry Laboratory, Department of Chemistry, National Institute of Technology Karnataka, Srinivasnagar, 575025, India
نشانی اینترنتی
https://www.abechem.com/article_722373_545fb5a0b8bed7e8ed6d57a736bb647d.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات