این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 24 آذر 1404
Analytical and Bioanalytical Electrochemistry
، جلد ۱۷، شماره ۵، صفحات ۳۴۸-۳۶۱
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Blood Cancer Detection using Quantum Dot based Electrochemical Sensors
چکیده انگلیسی مقاله
Quantum dot (QD)-enabled electrochemical sensors are emerging as a promising technology for the early diagnosis and continuous monitoring of blood-related cancers, including leukemia and lymphoma. These nanomaterials exhibit exceptional optical features, customizable fluorescence, and a large surface-to-volume ratio, making them highly effective for the sensitive and selective identification of cancer-specific biomarkers. Their ability to detect multiple analytes simultaneously enhances diagnostic efficiency by enabling the recognition of various biomarkers or circulating tumor cells (CTCs), which is vital for early-stage detection and tracking minimal residual disease (MRD). However, potential cytotoxicity, limited biocompatibility, and regulatory hurdles must still be addressed. Ongoing research is directed toward creating safer, non-toxic QDs, refining sensor functionality, and incorporating these sensors into portable diagnostic platforms. Furthermore, integrating optical and electrochemical detection methods—alongside innovations in surface chemistry and signal amplification—is anticipated to improve both sensitivity and clinical reliability. QD-based electrochemical sensors are expected to become essential tools for early, non-invasive blood cancer diagnostics and individualized patient care as these technologies evolve.
کلیدواژههای انگلیسی مقاله
Quantum dots,Electrochemical Biosensors,Hematologic malignancies,Leukemia,Lymphoma,Cancer markers,Circulating tumor cells (CTCs),Minimal residual disease (MRD)
نویسندگان مقاله
Abhigyan Ganguly |
Department of CSE-AI, Brainware University, Kolkata, India
Sandipan Biswas |
Department of CSE-AI, Brainware University, Kolkata, India
Nitai Paitya |
Department of CSE-AI, Brainware University, Kolkata, India
نشانی اینترنتی
https://www.abechem.com/article_724931_98f07a2500533254b00c44cb6d40e7e9.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات