این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۲۲، شماره ۲، صفحات ۱۲۰-۱۲۹

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Performances analysis of Sugar/EPR, Lithium Formate Monohydrate/EPR and Sulfamic acid/EPR dosimetry systems in evaluation of doses delivered during the prostate cancer treatment, using an anthropomorphic phantom
چکیده انگلیسی مقاله Introduction: The aim of this work is to test the suitability of the three dosimetry systems: sugar/EPR (Electron Paramagnetic Resonance), lithium formate monohydrate/EPR (LFM/EPR) and sulfamic acid/EPR in the control and assessment of the dose delivered in tumor volume and surrounding organs during radiotherapy treatment of prostate cancer. Thus, the study proposes to compare the doses calculated by the treatment planning system (TPS) with the doses measured by the three dosimetry systems used, in order to verify their ability to evaluate the clinical doses administered. Material and Methods: To perform this work, the various dosimeters studied were placed at the level of the tumor and the surrounding organs in a male anthropomorphic phantom. To simulate radiation therapy for prostate cancer, the phantom used was irradiated by 6 MV X-rays after careful implementation of a treatment plan for the determination and execution of the prescribed dose, using CT (Computed Tomography) imaging and TPS calculations. Results: The irradiated dosimeters were analyzed by EPR and the determined doses were compared to the doses calculated by the TPS system. The results obtained show that the doses measured by the studied dosimetry systems are similar to calculated doses. The sugar/EPR system appears to be more accurate than the other two dosimetry systems. Conclusion: The three dosimetry systems used show promise for applications as dosimeters in radiotherapy.
کلیدواژه‌های انگلیسی مقاله Sugar/EPR dosimetry, Lithium Formate Monohydrate/EPR dosimetry, Sulfamic acid/EPR dosimetry, anthropomorphic phantom, Prostate cancer radiotherapy

نویسندگان مقاله | Fatna ZAHIRI
Laboratory of Mathematics, Computer Science and Engineering Sciences, Faculty of Science and Technology, Hassan First University, Settat, Morocco


| Mohammed MIKOU
Laboratory of Mathematics, Computer Science and Engineering Sciences, Faculty of Science and Technology, Hassan First University, Settat, Morocco


| Redouane EL BAYDAOUI
Laboratory of Sciences and Health Technologies, Higher Institute of Health Sciences (ISSS), Hassan First University, Settat, Morocco


| Kamal Saidi
Laboratory of Sciences and Health Technologies, Higher Institute of Health Sciences (ISSS), Hassan First University, Settat, Morocco. Department of Radiotherapy, Sheikh Khalifa International University Hospital, Casablanca, Morocco


| Hanae EL GOUACH
Department of Radiotherapy, Sheikh Khalifa International University Hospital, Casablanca, Morocco



نشانی اینترنتی https://ijmp.mums.ac.ir/article_26377.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات