این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 19 آذر 1404
Archives of Anesthesiology and Critical Care
، جلد ۱۱، شماره ۴، صفحات ۵۸۵-۵۹۵
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
What Are the Most Common Ventilator Alarms in the ICU? An Integrative Review
چکیده انگلیسی مقاله
Background: Considering the vital role of the mechanical ventilator in providing respiratory support to patients, it is important and necessary to pay attention to and identify the common alarms of this device and to sensitize the medical team to these warnings. Methods: This integrative review study was conducted in order to evaluate both printed and non-printed studies. Searching was done from 20/09/2010 to 20/09/2023 based on Prisma 2009 guidelines in Scopus, PubMed, Embase, and ProQuest databases. The keywords included "pulmonary ventilator," "mechanical ventilators," "ventilator," "respirators," "alarm," "clinical alarms," and "alarm fatigue," and the articles were selected based on the entry criteria Results: Out of a total of 264 retrieved articles, 13 articles were included in the study. The obtained results indicated that the most frequent alarms were High PIP, High RR, and High/Low MV, which are not only important alarms, but also have high prevalence in the intensive care unit. Therefore, great attention should be paid while setting the alarm range and reacting to auditory and visual alarms. Conclusion: Failure to pay attention to alarms and setting them improperly has a significant effect on the medical team’s fatigue, which leads to a decrease in the quality of care. Therefore, using a correct management strategy in order to increase the medical team’s knowledge and reduce unnecessary alarms can play an effective role in improving the quality of the services provided to the patients hospitalized in special care units. Identifying the important alarms of mechanical ventilators and using the appropriate strategy to set the alarms correctly can increase the quality of the care provided for the patients under mechanical ventilation.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Yaser Saeed
Nursing Care Research Center, Clinical Sciences Institute and Nursing Faculty of Baqiyatallah University of Medical Sciences, Tehran, Iran.
| Neda Sanaie
Medical and Surgical Nursing Department, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| Shima Shirozhan
Department of Nursing, Health in Emergency and Disaster Research Center, Social Health Research Institute, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.
| Sorour Khari
School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| Ladan Sedighie
Medical and Surgical Nursing Department, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
نشانی اینترنتی
https://aacc.tums.ac.ir/index.php/aacc/article/view/1150
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات