این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Medical Signals and Sensors، جلد ۱۴، شماره ۸، صفحات ۱۰-۴۱۰۳

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Magnetic Resonance Image Radiomic Reproducibility: The Impact of Preprocessing on Extracted Features from Gross and High-Risk Clinical Tumor Volumes in Cervical Cancer Patients before Brachytherapy
چکیده انگلیسی مقاله Abstract Background:  Radiomic feature reproducibility assessment is critical in radiomics-based image biomarker discovery. This study aims to evaluate the impact of preprocessing parameters on the reproducibility of magnetic resonance image (MRI) radiomic features extracted from gross tumor volume (GTV) and high-risk clinical tumor volume (HR-CTV) in cervical cancer (CC) patients. Methods:  This study included 99 patients with pathologically confirmed cervical cancer who underwent an MRI prior to receiving brachytherapy. The GTV and HR-CTV were delineated on T2-weighted MRI and inputted into 3D Slicer for radiomic analysis. Before feature extraction, all images were preprocessed to a combination of several parameters of Laplacian of Gaussian (1 and 2), resampling (0.5 and 1), and bin width (5, 10, 25, and 50). The reproducibility of radiomic features was analyzed using the intra-class correlation coefficient (ICC). Results:  Almost all shapes and first-order features had ICC values > 0.95. Most second-order texture features were not reproducible (ICC < 0.95) in GTV and HR-CTV. Furthermore, 20% of all neighboring gray-tone difference matrix texture features had ICC > 0.90 in both GTV and HR-CTV. Conclusion:  The results presented here showed that MRI radiomic features are vulnerable to changes in preprocessing, and this issue must be understood and applied before any clinical decision-making. Features with ICC > 0.90 were considered the most reproducible features. Shape and first-order radiomic features were the most reproducible features in both GTV and HR-CTV. Our results also showed that GTV and HR-CTV radiomic features had similar changes against preprocessing sets.
کلیدواژه‌های انگلیسی مقاله Brachytherapy,gross tumor volume,high-risk clinical tumor volume,MRI,radiomics,reproducibility

نویسندگان مقاله | Mahdi Sadeghi
Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran


| Neda Abdalvand
1.Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran 3.Radiation Biology Research Center, Iran University of Medical Sciences, Tehran, Iran


| Seied Rabi Mahdavi
Student Research Committee, Department of Radiology Technology, Faculty of Allied Medicine, Kerman University of Medical Sciences, Kerman, Iran 5Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, BC, Canada


| Hamid Abdollahi
Student Research Committee, Department of Radiology Technology, Faculty of Allied Medicine, Kerman University of Medical Sciences, Kerman, Iran


| Younes Qasempour
Department of Radiation Oncology, Golestan Hospital, Ahvaz Jundishapour University of Medical Sciences, Ahvaz, Iran


| Fatemeh Mohammadian
6.Department of Radiation Oncology, Golestan Hospital, Ahvaz Jundishapour University of Medical Sciences, Ahvaz, Iran 7.Department of Medical Physics, School of Medicine, Ahvaz Jundishapour University of Medical Sciences, Ahvaz, Iran


| Mohammad Javad Tahmasebi Birgani
Department of Radiation Oncology, Golestan Hospital, Ahvaz Jundishapour University of Medical Sciences, Ahvaz, Iran


| Khadijeh Hosseini
Department of Radiation Oncology, Golestan Hospital, Ahvaz Jundishapour University of Medical Sciences, Ahvaz, Iran


| Maryam Hazbavi



نشانی اینترنتی http://jmss.mui.ac.ir/index.php/jmss/article/view/725
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Articles
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات