این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
نقش جهان - مطالعات نظری و فناوری های نوین معماری و شهرسازی، جلد ۶، شماره ۴، صفحات ۱-۱۴

عنوان فارسی Thermal Performance Evaluation of Low-E Coated Building Glazing Systems
چکیده فارسی مقاله Considering the determinant role of energy efficiency opportunities in the building sector, proposing guidelines and technical solutions in order to improve the thermal performance of glazing systems is in priority in Iran and other countries. In glazing systems, a substantial amount of radiative heat transfer results from absorption and emission. Applying low-E (low emissivity) coatings on the glazing system is a solution for reducing the radiative heat transfer by radiation in glazing systems, without a noticeable decrease of visible light transmittance. By selecting the proper glazing type, in a hot climate, the amount of solar heat gain can be reduced significantly. Vice versa, in cold climate, the heat loss by long wave radiation of inner surfaces can be reduced. In this paper, first, the thermal and optical characteristics of local clear and Low-E glasses have been measured in BHRC (Road, Housing & Urban Development (National) Research Center) laboratory, by the spectrophotometer and then the thermal performance of single and double glazing units, with and without low-E coating, in different orientations (North, South, East and West) are computed, compared and analyzed for cold (Ardebil) and hot (Bandar-Abbas) climates in Iran. The selection of these two cities is based on maximum heating and cooling degree day values obtained respectively for Ardebil and Bandar-Abbas. The simulation results indicate that using double clear glazing unit with low-E coating reduces the energy consumption significantly in very hot climates, using mostly electrical energy for cooling. In cold climates like Ardebil, double glazing with low-E coating has a minor impact on annual heating load, because of the great amount of thermal radiation, even in the cold season, the high cost of low-e coating and the considerable payback time, compared to the building life cycle.
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Thermal Performance Evaluation of Low-E Coated Building Glazing Systems
چکیده انگلیسی مقاله
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله بهروز محمد karia | behrouz mohammad
department of energy, road, housing amp;amp; urban research center, tehran 1463917151, iran

شاهین حیدری |
faculty of architecture, college of fine arts, university of tehran, tehran 14395-1561, iran
سازمان اصلی تایید شده: دانشگاه تهران (Tehran university)

مهدیه آبروش |
faculty of architecture, college of fine arts, university of tehran, tehran 14395-1561, iran
سازمان اصلی تایید شده: دانشگاه تهران (Tehran university)


نشانی اینترنتی http://bsnt.modares.ac.ir/article_16560_cbd1303c699450349129cdf702cab62a.pdf
فایل مقاله اشکال در دسترسی به فایل - ./files/site1/rds_journals/1294/article-1294-383801.pdf
کد مقاله (doi)
زبان مقاله منتشر شده fa
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات