این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 5 دی 1404
Journal of Rehabilitation Sciences and Research
، جلد ۳، شماره ۴، صفحات ۷۷-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
The Reliability of Smartphone and Goniometric Measurements of Hip Range of Motion
چکیده انگلیسی مقاله
Background: Range of motion is an essential component of the hip examination. Handling issues with the goniometer often create challenges when measuring hip passive range of motion (PROM). Recent generations of smartphones have emerged as an alternative instrument for the measurement of joint ROM. The purpose of this study was to investigate the intra-rater, inter-rater and inter-instrument reliability of smartphone and goniometric hip PROM. Methods: Two investigators measured hip PROM to a designated end position on 30 asymptomatic participants in a blinded within study design using two measurement methods, smartphone and goniometer. Relative reliability of smartphone and goniometric measurements of hip PROM was assessed using intraclass correlation coefficients (ICC). Absolute reliability of both measurement methods was assessed using paired t-tests, standard errors of measurement (SEM), and 95% limits of agreement (LOA). Results : Relative reliability ICCs ranged from 0.47-0.99 (intra-rater), 0.05-0.99 (inter-rater) and 0.25 -0.97 (inter-instrument). Inter-rater differences of smartphone hip measurements were non-significant, however, significant differences were found for all inter-rater goniometric hip measurements (p< 0.02). The comparison of the smartphone to goniometric measurements showed bias was present in 7 out to 12 hip measurements (p < 0.04). SEM ranged from 1° to 3° (intra-rater, inter-rater, and inter-instrument). LOA ranged from -6.8° - 5.1° (inter-rater) and -8.9° - 13.8° (inter-instrument). Conclusion : These findings support intra-rater reliability of both instruments when measuring hip PROM. Inter-rater reliability, however, was supported only for the smartphone. Due to systematic bias of inter-instrument measurements performed by one rater, caution should be used if the instruments are to be used interchangeably in order to quantify within session hip PROM.
کلیدواژههای انگلیسی مقاله
Hip, Goniometer, Smartphone, Range of motion, Reliability
نویسندگان مقاله
الیزابت s norris | elizabeth s norris
western kentucky university
امیلی رایت | emily wright
total fitness connection
shannon سیما | shannon sims
the medical center home care program
megan fuller | megan fuller
signature healthcare of bowling green
kurt neelly | kurt neelly
western kentucky university
نشانی اینترنتی
http://jrsr.sums.ac.ir/index.php/jrsr/article/view/143
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/343/article-343-404470.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Articles
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات