این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 26 آذر 1404
Journal of Reproduction and Infertility
، جلد ۱۸، شماره ۳، صفحات ۳۲۳-۶۵۵
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Value of "Three Dimensional Multidetector CT Hysterosalpingography" in Infertile Patients with Non-Contributory Hysterosalpingography: A Prospective Study
چکیده انگلیسی مقاله
Background: Infertility is a common health problem requiring imaging to delineate the anatomical causes in women. Three dimensional multi-detector computed tomography hysterosalpingography (3D-MDCT-HSG) offers an easy workup for uterine, tubal and peritoneal factors. Methods: To present the spectrum of uterine, tubal and peritoneal factors on 3D- MDCT-HSG and determine its diagnostic accuracy for female factor infertility, a prospective study was conducted on 25 infertile women with non-diagnostic HSG from November 2012 to March 2014. Sixty four slice MDCT acquired the scan during pre-ovulatory phase by contrast instillation into uterine cavity. A blinded reviewer interpreted the 3D-MDCT-HSG and results were compared with final diagnosis made on hystero-laproscopy in 22 patients. Diagnostic accuracy of 3D-MDCT-HSG for various factors was expressed as sensitivity, specificity, positive and negative predictive value. Results: MDCT-HSG demonstrated definite findings in 96% of patients having non-diagnostic HSG. In this study, tubal, uterine and peritoneal abnormalities were present in 68.75%, 56% and 32% of cases, respectively. 48 tubes in 25 patients were evaluated of which 22 tubes were blocked constituting the commonest finding present in 15 (60%) patients. The sensitivity, specificity, positive predictive value and negative predictive value for uterine factors was 83.33% ,100%, 100% and 96.84%, respectively, for tubal factors 93.55%, 94.68%, 85.29% and 96.83%, respectively and for peritoneal factors 62.5%, 92%, 71.43% and 88.46%, respectively. Mean effective radiation dose was 1.76±0.18 mSv in MDCT-HSG. Conclusion: 3D-MDCT-HSG can detect various factors responsible for female infertility especially tubal and uterine; in cases where HSG fails to clearly delineate the pathology.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
نشانی اینترنتی
http://www.jri.ir/article/707
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات