عنوان انگلیسی Microbiological qualificationof air, waterand dialysate in a haemodialysiscentre; a new focus on Legionella spp
چکیده انگلیسی مقاله Background and Objectives: The microbiological monitoring of the water used for haemodialysis is important especially for Legionella and non-fermentative bacteria since patients with end stage renal disease (ESRD) are suffering from deteriorated function of immune system. Materials and Methods: A total 50 water and dialysate samples were weekly collected over a period of 10 weeks from 5 sites. Total and faecal coliforms were determined by utilizing the most probable number (MPN) method. For isolation of Legionella, water samples were inoculated on a BCYE medium. DNA extraction was performed and was used to amplify 16S rRNA gene of Legionella species. Airborne bacteria were sampled using a single stage Andersen air sampler. Results: Out of total 50 water samples, 24 samples had bacterial contamination. The highest rate of Legionella contamination was observed in the storage tank (67 cfu/ml). Legionella was not isolated from the dialysate effluent samples. The highest rate of total bacterial count was related to the dialysate effluent and the maximum total count of coliforms was related to the reverse osmosis. The isolated bacteria were Gram-negative bacilli (mostly Pseudomonas isolates), Gram-positive cocci (mostly Micrococcus spp. ) and Gram-positive bacilli (mostly Bacillus spp. ). Six samples were contaminated with coliforms. No faecal coliform was isolated from the samples. Conclusion: These results indicated that dialysis machine is an important source of contaminations such as Staphylococcus, Pseudomonas and Legionella. Therefore an efficient prevention program is needed to eliminate bacterial contamination of dialysis water system. Moreover, in haemodialysis centres, periodic surveillance programs for microbiological qualification can lead to a better planning for disinfection of haemodialysis water systems.
کلیدواژه‌های انگلیسی مقاله Microbiological qualification,Haemodialysis,Legionella

نویسندگان مقاله سعید ناظمی | saeid nazemi
department of environmental health engineering, school of public health, shahroud university of medical sciences, shahroud, iran


مهدی میرزایی | mehdi mirzaii
school of medicine, shahroud university of medical sciences, shahroud, iran


سمیه یسلیانی | somayeh yaslianifard
department of microbiology, school of medicine, alborz university of medical sciences, karaj, iran


داود دربان ساروخلیل | davood darban sarokhalil
department of microbiology, school of medicine, iran university of medical sciences, tehran, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی ایران (Iran university of medical sciences)

سید سجاد خرم روز | seyyed sajjad khoramrooz
medicinal plant research center, yasuj university of medical sciences, yasuj, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی یاسوج (Yasouj university of medical sciences)

پیراسته نوروزی | pirasteh norozi
school of medicine, shahroud university of medical sciences, shahroud, iran


فاطمه داوردوست | fatemeh davardoost
school of public health, shahroud university of medical sciences, shahroud, iran



نشانی اینترنتی http://ijm.tums.ac.ir/index.php/ijm/article/view/820
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Articles
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات