این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Basic Medical Sciences، جلد ۲۰، شماره ۴، صفحات ۳۶۸-۳۷۹

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Effects of buprenorphine in the adrenal, thyroid, and cytokine intra-operative responses in a rat model (Rattus norvegicus): a preliminary study
چکیده انگلیسی مقاله Objective(s): Buprenorphine is a common analgesic in experimental research, due to effectiveness and having few side-effects, including a limited influence in the immune and endocrine systems. However, how buprenorphine affects cytokine levels and the adrenal and thyroid response during general anesthesia and surgery is incompletely understood. This study aimed to assess whether buprenorphine modulated significantly those responses in rats submitted to general anesthesia, mechanical ventilation, and surgical insertion of intravascular catheters. Materials and Methods: Animals were anesthetized with isoflurane, mechanically ventilated, and surgically instrumented for carotid artery and the femoral vein catheter placement. The test group (n=16), received buprenorphine subcutaneously before surgery, whereas the control group (n=16) received normal saline. Blood sampling to determine plasma levels of adrenocorticotropic hormone (ACTH), corticosterone (CS), total thyroxine (TT4), total triiodothyronine (TT3), thyroid-stimulating hormone (TSH), TNF-α, IL6, IL10, TNF-α, IL6, and IL10 mRNA was performed at 10 min after completion of all surgical procedures and at 90, 150, 240, and 300 min thereafter, with the animals still anesthetized and with mechanical ventilation. Results: Buprenorphine-treated animals had higher levels of ACTH, CS, and TT4 at several time points (P< 0.05) and TSH and TT3 at all-time points (P< 0.05). They also had increased IL10, TNF-α, and IL10 mRNA levels. Conclusion: In this model, buprenorphine significantly modulated the intra-operative cytokine and endocrine response to anesthesia, mechanical ventilation, and surgical placement of intravascular catheters. The mechanism and significance of these findings remain undetermined. Researchers should be aware of these effects when considering the use of buprenorphine for analgesic purposes.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله nuno m félix | nuno m félix
centro de investigação interdisciplinar em sanidade animal ciisa faculdade de medicina veterinária, university of lisbon ulisboa , lisboa, portugal


rodolfo o leal | rodolfo o leal
centre hospitalier vétérinaire fregis, arcueil, france


i گوی thollot | i goy thollot
siamu, vetagro sup, marcy l’étoile, france – université de lyon, vetagro sup, ea apcse agressions pulmonaires et circulatoires dans le sepsis, marcy l’etoile, france


رونالد s walton | ronald s walton
animal medical center of seattle shoreline, washington, usa


solange a گیل | solange a gil
centro de investigação interdisciplinar em sanidade animal ciisa faculdade de medicina veterinária, university of lisbon ulisboa , lisboa, portugal


luísa m mateus | luísa m mateus
centro de investigação interdisciplinar em sanidade animal ciisa faculdade de medicina veterinária, university of lisbon ulisboa , lisboa, portugal


آنا s matos | ana s matos
unidemi, departamento de engenharia mecânica e industrial, faculdade de ciências e tecnologia, universidade nova de lisboa, caparica, portugal


ماریا m r e niza | maria m r e niza
centro de investigação interdisciplinar em sanidade animal ciisa faculdade de medicina veterinária, university of lisbon ulisboa , lisboa, portugal



نشانی اینترنتی http://ijbms.mums.ac.ir/article_8576.html
فایل مقاله دریافت فایل مقاله
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Article
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات