این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۴، شماره ۳، صفحات ۱۶۷-۱۷۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of Tumor Control and Normal Tissue Complication Probability in Head and Neck Cancers with Different Sources of Radiation: A Comparative Study
چکیده انگلیسی مقاله
Introduction: The ultimate goal of radiation treatment planning is to yield a high tumor control probability (TCP) with a low normal tissue complication probability (NTCP). Historically dose volume histogram (DVH) with only volumetric dose distribution was utilized as a popular tool for plan evaluation hence present study aimed to compare the radiobiological effectiveness of the cobalt-60 (Co-60) gamma photon and 6MV X-rays of linear accelerators (Linac) in the radiotherapy of head and neck tumors. Materials and Methods: TCP and NTCP were calculated using DVH through the BIOPLAN software developed by Sanchez-Nieto and Nahum . The treatment planning was performed for all the patients using both treatment modalities (i.e., Co-60 and 6 MV Linac). The TCP was also manually calculated using a mathematical formula proposed by Brenner's et al. Results: The average TCP calculated by the BIOPLAN for Co-60 and 6 MV X-rays were 44.6% and 60.8%, respectively. Furthermore, the average NTCPs obtained for the organ at risk, namely optic nerve, for Co-60 and 6 MV X-ray were 0.24 % and 0.03 %, respectively. Regarding the spinal cord, the average NTCPs for Co-60 gamma photon and 6 MV X-ray of Linac were 0.05 % and 0.002%, respectively. Conclusion: As the findings of the present study indicated, Co-60 unit could provide comparable TCP along with minimal NTCP, compared to the high-cost technologies of Linac. The design of treatment plans based on the radiobiological parameters facilitated the judicious choice of physical parameters for the achievement of high TCP and low NTCP.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
anoop srivastava | anoop srivastava
department of radiation oncology, dr. ram manohar lohia institute of medical sciences, vibhuti khand gomti nagar, lucknow -226010 india
madhup rastogi | madhup rastogi
department of radiation oncology, dr. ram manohar lohia institute of medical sciences, vibhuti khand gomti nagar, lucknow -226010
surendra میشرا | surendra mishra
department of radiation oncology, dr. ram manohar lohia institute of medical sciences, vibhuti khand gomti nagar, lucknow -226010
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_8659.html
فایل مقاله
دریافت فایل مقاله
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات