این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 30 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۴، شماره ۲، صفحات ۶۶-۷۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Half Beam Block Technique in Breast Cancer and It’s Dosimetric Analysis using different Algorithms
چکیده انگلیسی مقاله
Introduction: Single isocentre half-beam block (HBB) technique permits the avoidance of hot and cold spots. This technique is very useful in sparing the underlying ipsilateral lung and heart, if the left breast is treated. The major advantage of this technique is that it facilitates the complete sparing of both contralateral breast and lung. Regarding this, the present study aimed to analyse the dosimetric results obtained from the HBB technique in the treatment of breast cancer using three different algorithms. Materials and Methods: For the purpose of the study, a total dose of 5000 cGy was prescribed to the planning target volume (PTV) in 25 fractions per fraction daily, five days a week. The PTV was derived by using 4-7 mm isotropic expansion of the clinical target volume (CTV) clipping 1-3 mm from the patient's surface in the breast-conserving cases. Three plans were created for each patient using three different algorithms, including convolution, fast superposition, and superposition with the same parameters. Results: The mean doses of PTV-breast and CTV-supraclavicular fossa (SCF) were tabulated and analysed. In the PTV-breast, the maximum and minimum mean doses were 5428.8 and 4930.2 cGy, which were observed in the fast superposition and convolution algorithms, respectively. In the CTV-SCF, the maximum and minimum mean doses were 5428.8 and 5126.8 cGy, respectively, detected in only fast superposition algorithm. Conclusion: As the findings of the present study indicated, the convolution algorithm gives slightly better dosimetric results in breast cancer treatment, compared to the fast superposition and superposition algorithms. Therefore, it is prudent to apply the HBB technique with convolution algorithm using the Elekta XiO planning system in the treatment of breast cancer including supraclavicular lymph node metastasis.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
shahnawaz انصاری | shahnawaz ansari
apollo hospital,bilaspur c.g
subrat satpathy | subrat satpathy
apollo hospital bilaspur c.g
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_8528.html
فایل مقاله
دریافت فایل مقاله
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات