عنوان انگلیسی Analysis of Accuracy of Interpolation Methods in Estimating the Output Factors for Square Fields in Medical Linear Accelerator
چکیده انگلیسی مقاله Introduction: To estimate the accuracy levels of Lagrange, Newton backward interpolation, and linear interpolation methods in estimating the output factors for square fields used in linear accelerator for 6 MV photons at various depths. Materials and Methods: Ionization measurements were carried out in radiation field analyzer in linear accelerator for 6 MV beams at the depths of 5 and 10 cm by 0.6 cc Farmer-type ionisation chamber. Dosimetry was performed by ion collection method with 0.5 cm2  interval for square fields from 4 × 4 cm2 to 40 × 40 cm2 field sizes. The measured output factor values for 10 square field sizes with equal interval were taken for interpolating the intermediate square field size values. The Lagrange and Newton backward methods were used for predicting the intermediate output factors. Results: The percentage of deviation from the measured value was estimated for all the three methods. The calculated output factor values of the two proposed methods were compared with the standard linear interpolation method used in routine clinical practice. It was observed that the Lagrange and Newton backward methods were not significantly different from the measured value (P=0.77). The linear interpolation values were significantly different from the measured value (P< 0.01). Conclusion: It is recommended to use the Lagrange and Newton backward interpolation methods to estimate the intermediate output factors to increase accuracy in treatment delivery. The routine linear interpolation method can be applied only for small intervals. This proposed interpolation method is highly associated with the measured values in all the interval levels.
کلیدواژه‌های انگلیسی مقاله Field Size, Interpolation, Linear Accelerator, Output factor

نویسندگان مقاله athiyaman mayilvaganan | athiyaman mayilvaganan
sp medical college, bikaner, rajasthan, india


hemalatha athiyaman | hemalatha athiyaman
assistant professor,department of radiological physics,sp medical college


arun chougule | arun chougule
professor and head,department of radiological physics, sms medical college,jaipur, rajajsthan,india


کومار hs | kumar hs
sp medical college,bikaner,rajasthan,india



نشانی اینترنتی http://ijmp.mums.ac.ir/article_8467.html
فایل مقاله دریافت فایل مقاله
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات