این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 1 دی 1404
Iranian Journal of Medical Physics
، جلد ۱۴، شماره ۲، صفحات ۱۰۴-۱۱۳
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography
چکیده انگلیسی مقاله
Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomography (CBCT) images were taken after bony anatomy alignment by using two orthogonal radiographic images, as well as CBCT images. Dose distributions and dose volume histograms (DVH) for all the original and CBCT plans were obtained. Maximum, as well as mean doses and volumes of the bladder, rectum, and both femoral heads were recorded for each CBCT plan and compared with the original CT plan. For all the studied body parts, the differences in DVH between CBCT plans and original CT plan were calculated and compared. Results: Considering all the 75 CBCT images for the 15 patients, average of changes in mean doses and volumes were 17.8%, 41.8%, 7.1%, and 36.8% for the bladder and rectum, respectively. There was a significant (P< 0.05) negative correlation between mean bladder dose and volume, while a weak and positive correlation was found between mean dose and volume of rectum in our patients. Conclusion: Our results showed that changes in volumes of the bladder and rectum alter their received inter-factional mean doses. Further attention to the volume variations of the bladder and rectum during a radiotherapy course is recommended for more accurate IGRT treatment.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
اصغر مصباحی | asghar mesbahi
tabriz university of medical sciences
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تبریز (Tabriz university of medical sciences)
dogukan akcay | dogukan akcay
2. radiation therapy department, dokuz eylul university hospital, izmir, turkey
اسماعیل volkan tekcan | ismail volkan tekcan
3. medical physics department, institute of health sciences, dokuz eylul university, izmir, turkey
zumre arican alikus | zumre arican alikus
2. radiation therapy department, dokuz eylul university hospital, izmir, turkey
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_8529.html
فایل مقاله
دریافت فایل مقاله
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات