Iranian Journal of Medical Physics، جلد ۱۴، شماره ۱، صفحات ۱-۷

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Quality Control Assessment of Conventional Radiology Devices in Iran
چکیده انگلیسی مقاله Introduction Quality control (QC) techniques are used in monitoring and maintenance of the components of an x-ray system. QC of radiology devices plays a significant role in reduction of medication dose and optimization of image quality. This study aimed to conduct QC tests on randomly selected radiology devices, installed in diagnostic imaging departments of Iran. Materials and Methods In total, quality control tests were conducted on 51 conventional radiology devices installed in 20 cities of Iran in order to assess the accuracy of peak kilovoltage  (kVp), exposure time, exposure linearity and reciprocity, reproducibility of exposure and determination of half-value layer (HVL) using a calibrated Mult-O-Meter. Results In this study, 38.6% of devices had intolerable variance of kVp accuracy. The results of 34.5% of devices were out of the acceptable limits in exposure time accuracy test. In 46.7% and 53.1% of devices, variance was greater than the acceptable range for exposure linearity and exposure reciprocity, respectively. In terms of reproducibility of exposure test, the reproducibility variance and percentage of tube output variations in 19.4% of devices exceeded the limits. Moreover, the thickness of first HVL was lower than the acceptable limit in 14.7% of devices. Conclusion According to the results of this study, there were wide variations in QC test results, perhaps mainly due to the fact that it is not an obligation to implement QC programs in Iran. The most important problems were non-reciprocity of exposure, nonlinearity of exposure with milliampere-second (mAs), kVp and timer inaccuracy. Involvement of medical physicists, radiologists and radiographers in the implementation of QC programs at various stages of development, installation and use of equipment should enable the gradual improvement in equipment performance.
کلیدواژه‌های انگلیسی مقاله Quality Control, Diagnostic X-Ray, Radiology

نویسندگان مقاله محسن اسدی نژاد | mohsen asadinezhad
department of radiology technology, school of paramedical sciences, mashhad university of medical sciences

سازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)

محمد تقی بحرینی طوسی | mohammad taghi bahreyni toossi
professor of medical physics, mashhad university of medical sciences, mashhad, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)

علی ابراهیمی نیا | ali ebrahiminia
assistant professor of medical physics, biochemistry and medical physics dept., school of medicine, guilan university of medical sciences, rasht, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی گیلان (Guilan university of medical sciences)

معصومه گیاهی | masoumeh giahi
student of radiology technology, department of radiology technology, school of paramedical sciences, mashhad university of medical sciences, mashhad, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)


نشانی اینترنتی http://ijmp.mums.ac.ir/article_8402.html
فایل مقاله دریافت فایل مقاله
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات