این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 19 آذر 1404
International Journal of Radiation Research
، جلد ۱۵، شماره ۳، صفحات ۲۷۵-۲۸۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Monte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry
چکیده انگلیسی مقاله
Background: The lack of lateral electronic disequilibrium (LED) becomes a main problem in small field. This factor affects the dose in target volume cannot predict correctly. In addition, utilization of high-energy linear accelerator (10 MV) can emit some unwanted particles (electron contamination). Therefore, the aim of this study was to characterize head linear accelerator (linac) Varian Clinac iX 10 MV photon beam for square small field size (1×1, 2×2, 3×3, 4×4 and 5×5 cm2) using Monte Carlo (MC) simulation. Materials and Methods: The commissioning process for this linac, has been conducted for field size 6×6, 10×10 and 20×20 cm2 by comparing the measurement and MC simulation data. Head linac simulation was performed with BEAMnrc and dose calculation with DOSXYZnrc. The phase space (phsp) data from BEAMnrc was analyzed using BEAMDP to get the particles information in scoring plane. Results and Discussion: The scatter angle of particles depends on the field size. This factor affects the penumbra width in water phantom. On the other hand, PDD data show that the depth of maximum dose and penumbra width in small field shifted correspond with the number of scatter particle. The difference of relative output factor between measurement and MC results were found less than 2%. However, the 2% difference was still acceptable in photon beam dosimetry. Conclusion: From this simulation, the electron contamination give contribution in surface dose of water phantom about 13.0581% and less than 1% for field size 10×10 cm2 and small field size, respectively.
کلیدواژههای انگلیسی مقاله
Photon beam, Monte Carlo, small field dosimetry.
نویسندگان مقاله
s yani | s. yani
1department of physics, faculty of mathematics and natural sciences, institute technology bandung, indonesia
میرفرهاد rhani | m f rhani
2department of radiation oncology, national university cancer institute singapore, singapore
r c x soh | r c x soh
3school of physical and mathematical sciences, nanyang technological university, singapore
f haryanto | f. haryanto
4department of physics, faculty of mathematics and natural sciences, institute technology bandung, indonesia
i عارف | i. arif
5department of physics, faculty of mathematics and natural sciences, institute technology bandung, indonesia
نشانی اینترنتی
http://ijrr.com/browse.php?a_code=A-10-1-676&slc_lang=en&sid=en
فایل مقاله
دریافت فایل مقاله
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
مرور و بررسی کلی
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات