این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 26 آذر 1404
Iranian Journal of Nursing and Midwifery Research
، جلد ۱۹، شماره ۵، صفحات ۴۷۳-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Comparison of the effects of two levels of negative pressure in open endotracheal tube suction on the physiological indices among patients in intensive care units
چکیده انگلیسی مقاله
ABSTRACT Background: Most of the patients admitted in the intensive care units (ICUs) require an endotracheal tube and mechanical ventilation. In order to clear and maintain patency of the airways, endotracheal suctioning is required. Therefore, the least detrimental way of endotracheal tube suctioning which can diminish the complications should be selected. The present study aimed to compare the effect of two levels of negative pressure (100 mmHg and 200 mmHg) in open endotracheal tube suction on the physiological indices among patients in the ICUs. Materials and Methods: In this single-blind clinical trial, 60 patients meeting the inclusion criteria were selected by convenience sampling and randomly allocated in two groups. First group of patients were suctioned with negative pressure of 100 mmHg and the second group with 200 mmHg. Effects of two levels of suction pressure on oxygen saturation (SPO2) and heart rate (HR) values were measured and recorded at four time points. Repeated measure analysis of variance (ANOVA), Chi-square test, and independent t-test were adopted to analyze the data. Results: In the two groups consisting of totally 60 subjects (30 in each group), 34 subjects were males and 26 were females, with a mean age of 60.63 years (minimum 18 years and maximum 75 years). Repeated measure ANOVA showed a signifi cant difference in the mean SpO2 and HR before, during, and 5 and 20 min after suction within each group (P < 0.05), but not between the two groups (P > 0.05). Conclusions: The present study revealed that with regard to the detrimental effect of endotracheal tube suctioning on arterial oxygen saturation and HR, suctioning with negative pressure of 200 mmHg is considered to be a low-risk procedure compared to suctioning with negative pressure of 100 mmHg, if standard procedures in open suction system are followed.
کلیدواژههای انگلیسی مقاله
Intensive care unit, physiological indices, suction
نویسندگان مقاله
حجت اله یوسفی | hojatollah yousefi
جهانبخش وحدت نژاد | jahanbakhsh vahdatnejad
احمدرضا یزدان نیک | ahmad reza yazdannik
نشانی اینترنتی
http://www.ijnmr.mui.ac.ir/index.php/ijnmr/article/view/1073
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات